Best Answer

For convenience, they should be as close together as possible, especially in a kitchen or workshop, but for cost, they are usually placed at the maximum limit permitted by code, such as would permit a standard 6-foot lamp cord to reach anywhere along any wall mor than 14 inches wide, without crossing a doorway.

I installed 27 outlets in my kitchen, with at least four on every counter and island. Code only required 8.

User Avatar

Wiki User

16y ago
This answer is:
User Avatar
More answers
User Avatar

Wiki User

15y ago

This depends on your local building code. Common placement would be at a maximum of 12 feet apart, and a max of 6 feet from any door opening.

This answer is:
User Avatar

User Avatar

Wiki User

10y ago

You can put them as close together as you want but you must have 1 outlet a minimum of every 12 feet. Doorways do not count. If there is a wall that is 2' or more it must have an outlet.

This answer is:
User Avatar

Add your answer:

Earn +20 pts
Q: How far apart from each other are electrical receptacles placed?
Write your answer...
Submit
Still have questions?
magnify glass
imp
Continue Learning about Electrical Engineering

What other forms of energy can electrical energy be converted into by a load?

Anything device can transform electrical energy into other form of energy. This is called an electrical load.


Where do you find receptacle requirements back side of peninsula in kitchen?

The requirements for receptacles and any other necessary additions will usually be found on the blueprints. If they are not, its best to consult with the contractor or builder to make sure they are included.


What is electrical engery changed to?

It can be converted to most other types of energy.


How much money should an electrical contractor charge a company for contracting under his electrical license?

In California you cannot do this unless the company is placed on your license. The qualifying provisions would be such as an RME. If you do this you become totally liable for any work done by the other company, and I believe if you get caught doing this you may loose your license. Before doing this I would strongly advise you to contact your State Contractors License Board for further guidelines and assistance. This other company should hire you to perform the necessary work. If you are not able to perform this work yourself then consider hiring qualified electricians to work for you as employees and perform the work.


What is the function of an electrical engineer in telecom sector?

Electrical Engineer in telecom sector is as important as other Engineer as Civil, Telecom etc, as all the system runs on Electrical but now a days, as per market requirement, you should keep know how about other fileld also. But now a days in different fields every one think that he is misfit and the other is best then him. So we should change over self time to time with respect to the requirement of time.

Related questions

How do you wire multiple receptacles?

The receptacles will be wired in parallel with each other.


Electrical receptacles should be at least above floor level to reduce the risk of igniting spilled fuel vapors or other flammable liquids?

4


Is 26 receptacles wired on one 15 amp breaker up to code or standard practice for residential 26 receptacles include 10 can lights 4 other lights 12 outlets?

NO! You are drastically in excess of electrical code requirement. A 15 amp circuit should not exceed eight total receptacles and/or lighting devices.


An electrical circuit with components placed one after the other?

series circuit


Are there any electrical code issues with bathroom or kitchen light fixtures that have multiple plug receptacles with built-in GFI capabilities?

If the fixture has a built-in GFCI, there are no issues other than NO electrical fixtures in a bath or shower unless they are made for that purpose.


What happens when two like poles are placed near each other?

they create an electrical current


Why do cell phones smoke when pulled apart?

They probabaly smoke because of the tampering of the electrical wiring or other part of the phone


Could you get the watts for certain sockets?

Yes, very easily. Receptacles and other electrical devices are rated in amperage that the device can use or handle. Take that amperage and multiply it by the voltage that the device is rated for. The answer will be in watts. This wattage will be the maximum that is allowed from the receptacle or any other device.


Does the NEC code allow multiple 20A receptacles on a 20A circuit Put another way does a 20A receptacle with T shaped neutral slots imply that no other outlets are that circuit?

The National Electrical Code (US) allows up to thirteen 20 amp receptacles on a 20 amp circuit. 120V x 20A = 2400 VA each duplex receptacle is calculated at 180 VA 2400 / 180 = 13.3333 receptacles, since you can't put a third of a receptacle in, you have to round down to 13.


What are the two basic specifications that electrical receptacles are based on?

One basic specification that electrical receptacles are based on is the amount of amperage that the receptacle can legally handle. The other basic specification is the amount of voltage that the receptacle can legally handle. This is the reason that there are so many different types to choose from. When buying a receptacle you should be armed with the knowledge of what the voltage is going to be and what the load amperage is going to be to get the proper receptacle. Each receptacle has different pin configurations for voltage and amperage. This is a safety factor so that inter changeability can not happen.


If 2 barometers are placed apart by 1 kilometer with one shower higher pressure than the other what will happen to the air between them?

A wind will blow.


Gfi receptacle first in a line of seven other receptacles in new construction that works fine without the load of the other receptacles but does not work when you add the additional receptacles?

There must be leakage current in the down stream receptacles It is going to be a trial and error method of finding the leak. Remove the GFI and make a through connection to the downstream receptacles Now go to first receptacle and install the GFI. If it holds the fault is further down stream. Keep going down the line until you find the fault. When the GFI trips and won't reset it will be the up stream feeder. Check the feeder wire for cuts or scrapes in the insulation. Replace this feeder.