First, check the circuit breakers; make sure they are all ON.
Find out if any other outlets on the same breaker are working; it's always possible that a breaker is faulty.
If the breaker is on and everything else on the circuit is working, it could be as simple as a poor connection inside the outlet.
Also even though the outlet is not a GFCI, it may be fed from a GFCI outlet. Check near by outlets to see if any are GFCI and are tripped.
If you have any question about the functionality of your GFCI, you should have it replaced. You can certainly verify that the GFCI is still functioning by using the test button, but the light gives added assurance that the circuit is functioning properly.
Yes, but you can feed multiple outlets from one GFCI outlet. Make the first outlet fed in the cicuit a GFCI. Search for GFCI outlet with Google, etc. and I'm sure you will find an explanantion of how. Most GFCI's come with instructions also.
In a word NO, that will not cause either GFCI to trip. The correct term is GFCI (Ground Fault Circuit Interrupter)
A load of 1600 watts should be placed on a 20 amp 120 volt GFCI outlet.
It is a Ground Fault Circuit Interrupter or GFCI. It can either be equipped in your electric panel as a GFCI breaker, or in a GFCI outlet which also lets you extend the GFCI protection to other outlets "down the line" from the GFCI outlet.
If you have any question about the functionality of your GFCI, you should have it replaced. You can certainly verify that the GFCI is still functioning by using the test button, but the light gives added assurance that the circuit is functioning properly.
Ground wire is loose or disconnected somewhere in that circuit.
Not if the GFCI breaker is supplying the circuit you are wanting to put the GFCI receptacle into.
Yes, but you can feed multiple outlets from one GFCI outlet. Make the first outlet fed in the cicuit a GFCI. Search for GFCI outlet with Google, etc. and I'm sure you will find an explanantion of how. Most GFCI's come with instructions also.
No, except that you insert the wires into the holes on the back of the outlet. The power in connects to the LINE side of the outlet and power out connects to the LOAD side of the outlet. This is clearly marked on the back of the outlet. This will not only protect the outlet with the GFCI installed but all outlets receiving their power from that GFCI. If you do not want to protect the outlets receiving power from the outlet then connect that outgoing wire to the LINE side also. But know that only the outlet with the GFCI will be protected and all other outlets will not be GFCI protected.
Yes you can. Lots of blow dryers have GFCI protection built in.
In a word NO, that will not cause either GFCI to trip. The correct term is GFCI (Ground Fault Circuit Interrupter)
I assume you are hard wiring it and not plugging it in. The power coming into the GFCI outlet connects to the line side of the GFCI outlet. If you want the outdoor timer protected by the GFCI then connect the wire going to the timer to the load side of the outlet. If you do not want the timer protected then connect it to the line side. On the back of the GFCI if you look closely you will see Line & Load marked on the back.
Click the link.
A down stream receptacle that is connected to the upstream GFCI will be protected. If the downstream receptacle senses a fault the upstream GFCI will trip.
A load of 1600 watts should be placed on a 20 amp 120 volt GFCI outlet.
GFCI Breakers are quite a bit more expensive than a GFCI outlet. More often than not a typical residence will need only a handful of GFCI outlets that combined together will be cheaper than a GFCI breaker. If you need to protect a series of outlets with GFCI protection you can simply connect the rest of the outlets on that same circuit downstream from the first outlet on the line and make that the GFCI. All you have to do is connect all the other outlets to the LOAD side of the GFCI outlet. If a GFCI fault occurs in any of the outlets down stream they will trip that very first GFCI plug you placed and keep you safe.