A double pole breaker has one pole attached to one side of your breaker panel's bus or hot leg, and another pole attached to another hot leg or bus, if it is in a residential panel (in the US) each leg of the breaker is 120 volts to ground or neutral and 240 hot leg to hot leg. The 15 amp indicates that the breaker will trip if the circuit exceeds 15 amps across the two outputs of the breaker.

User Avatar

Wiki User

9y ago
This answer is:
User Avatar
User Avatar

Gary Mason

Lvl 1
1y ago
doulble switch circult breaker only half is providing power

Add your answer:

Earn +20 pts
Q: What is a 15 amp double pole breaker?
Write your answer...
Submit
Still have questions?
magnify glass
imp
Continue Learning about Natural Sciences

Can you use a double pole 15 amp breaker in place of a 20 amp single pole breaker for a 12000 BTU air conditioner?

If the 12,000 BTU A/C only requires 20 amps to run then yes you can use the same 12 gauge wire but you cannot change it to a 15 amp breaker. You will need to install a 20 amp double pole breaker. If it requires more than 20 amps you will have to replace the wiring and breaker.


Can you use two 15 amp single pole breakers in place of a double pole 30 amp breaker?

Yes. An everyday occurrence of this circuitry is in your kitchen counter split receptacles. The top half of the receptacle is a 15 amp circuit and from the same breaker the bottom half of the receptacle is another 15 amp circuit. A two pole single handle breaker is a common trip. If one of the circuits fed from the breaker faults the other connected circuit will shut off also. If you are talking about slot position in a breaker panel, you can remove the two pole breaker and install two single pole breakers.


Have 30 amp double pole need 15 amp 120v?

Remove the 30 amp double pole breaker and install at least one single pole 15 amp breaker. It is best if the other slot is not left open so if you have another single pole breaker of any size install it in the 2nd spot so it isn't open when you replace the cover on the panel. For your 15 amp circuit you need #14 gauge copper wire or larger with a hot, neutral, and ground. Your 30 amp circuit was probably wired with #10 gauge conductors. These will probably work on your 15 amp circuit but it may be difficult to connect #10 conductors to devices.


What breaker will interchange with American Switch Company?

Replacement for American Switch single pole 15 amp circuit breaker


Can you change a 250v 15 amp breaker with a 115v15 amp breaker?

No, it would not be safe because 250v is too high for that breaker. <<>> In North America all household breakers are rated at 120/240 volts. A 250 volt 15 amp breaker would would be a two pole breaker and take up two slots in the distribution panel. This can be pulled out and replaced with two separate 15 amp breakers or one 15 amp breaker and a slot panel filler to cover the second slot.

Related questions

Is a double throw 15amp breaker the same as a 30 amp breaker amp?

You have a double pole breaker for 240Volt supply. The maximum current is 15 amp.


Can you use a double pole 15 amp breaker in place of a 20 amp single pole breaker for a 12000 BTU air conditioner?

If the 12,000 BTU A/C only requires 20 amps to run then yes you can use the same 12 gauge wire but you cannot change it to a 15 amp breaker. You will need to install a 20 amp double pole breaker. If it requires more than 20 amps you will have to replace the wiring and breaker.


Can you use two 15 amp single pole breakers in place of a double pole 30 amp breaker?

Yes. An everyday occurrence of this circuitry is in your kitchen counter split receptacles. The top half of the receptacle is a 15 amp circuit and from the same breaker the bottom half of the receptacle is another 15 amp circuit. A two pole single handle breaker is a common trip. If one of the circuits fed from the breaker faults the other connected circuit will shut off also. If you are talking about slot position in a breaker panel, you can remove the two pole breaker and install two single pole breakers.


Have 30 amp double pole need 15 amp 120v?

Remove the 30 amp double pole breaker and install at least one single pole 15 amp breaker. It is best if the other slot is not left open so if you have another single pole breaker of any size install it in the 2nd spot so it isn't open when you replace the cover on the panel. For your 15 amp circuit you need #14 gauge copper wire or larger with a hot, neutral, and ground. Your 30 amp circuit was probably wired with #10 gauge conductors. These will probably work on your 15 amp circuit but it may be difficult to connect #10 conductors to devices.


Can I replace a 50 amp 240v dryer outlet with a std 15 amp 240 volt outlet?

Theoretically yes if you remove the two pole 50 amp breaker and replace it with a 2 pole 15 amp breaker. This has to be done because the new receptacle is only rated at 15 amps and can not be protected by a breaker any larger than 15 amps.Physically this is not going to happen due to the fact that you will not be able to connect the existing #6 conductor, which fed the 50 amp dryer receptacle, under the terminals of the new 2 pole 15 amp breaker.


What breaker will interchange with American Switch Company?

Replacement for American Switch single pole 15 amp circuit breaker


What circuit breaker will interchange with American Switch Company?

Replacement for American Switch single pole 15 amp circuit breaker


Can you change a 250v 15 amp breaker with a 115v15 amp breaker?

No, it would not be safe because 250v is too high for that breaker. <<>> In North America all household breakers are rated at 120/240 volts. A 250 volt 15 amp breaker would would be a two pole breaker and take up two slots in the distribution panel. This can be pulled out and replaced with two separate 15 amp breakers or one 15 amp breaker and a slot panel filler to cover the second slot.


Can you switch from 15amp to 20amp on a double pole breaker?

The minimum size wire a 20 amp breaker needs to be connected to is a #12 wire. The 15 is probably connected to a #14 right now which is only rated for 15 amps. Remember the breaker is sized to the wires ampacity not the load .


How do you turn a 30 amp circuit into a 15 amp cicuit?

Replace the 30 Amp Breaker with a 15 Amp breaker.


What size breaker is needed for 208 volts 6 amps using Ohm's law?

20 amp In North America code states a two pole 15 amp breaker will do the job.


Can a double pole 15 amp breaker help?

No. In North America a double pole breaker is used to obtain a voltage of 240 volts from the distribution panel. What ever the amperage rating stamped on the handle of the breaker is, that is the amperage that the breaker will trip at.