64 amps. The longer the run the more volt drop you get, but generally 64 amps.
64 AMPS
what is the current capacity 3 core 16sq mm swa
If 16mm is the overall diameter of the cable, yes - If that's the diameter of one core, then no.
For a 16mm² cable, the appropriate circuit breaker size typically ranges from 63A to 80A, depending on the specific application and the current-carrying capacity of the cable. It is essential to consider factors such as the installation method, ambient temperature, and any potential load characteristics. Always consult local electrical codes and standards, or a qualified electrician, to ensure proper sizing and safety.
Using a 10mm cable for a 50 A breaker is generally not recommended, as it may not be sufficient to safely handle the current. The appropriate cable size depends on various factors, including the length of the run and the installation conditions. Typically, a larger cable, such as 16mm² or 25mm², is recommended for a 50 A breaker to ensure safety and minimize voltage drop. Always consult local electrical codes and a qualified electrician for specific applications.
64 AMPS
Maximum is 85A but exceeding 3 metres or running within trunking / insulation material may need to be higher
what is the current capacity 3 core 16sq mm swa
If 16mm is the overall diameter of the cable, yes - If that's the diameter of one core, then no.
The largest size of twin and earth cable available is typically 16mm² in the UK market. This size is commonly used for higher current applications such as cooker circuits or shower circuits.
For a 16mm² cable, the appropriate circuit breaker size typically ranges from 63A to 80A, depending on the specific application and the current-carrying capacity of the cable. It is essential to consider factors such as the installation method, ambient temperature, and any potential load characteristics. Always consult local electrical codes and standards, or a qualified electrician, to ensure proper sizing and safety.
The power capacity of a 16mm armored cable depends on factors like voltage and cable insulation. In general, a 16mm armored cable can handle power up to around 5-6 kilowatts for domestic use and up to 7-8 kilowatts for industrial use at a standard voltage of 230V. It's best to consult a qualified electrician or refer to manufacturer specifications for accurate information.
The current carrying capacity of a cable depends on factors such as its material, size, and insulation. It is typically rated in amperes (A) and indicates the maximum current that the cable can safely carry without overheating. Exceeding this rating can pose a fire hazard or damage the cable.
If you are in the U.K. to supply and install an earth rod, earth cable and earth inspection box breaks down as follows: Labour 1.5 hrs £52.50 earth rod £ 9.00 15 Mts 16mm earth wire £15.00 Inspection box £ 8.00 ----------- £84.50
A large cable for earthing is to allow for the possibility of a very large current which would melt a smaller one thus removing the protection it is supposed to provide.