It's the voltage:
HT high voltage
LT low voltage
Tension = voltage (French?)
Sir I am Imran khan in nepal my problem is 6000KVA Step down Transformer is not charging. Transformer Pri- 33000V /105A Sec- 6900V / 502Atransformer all test (open & short circuit ) good . but problem is HT(IR)= value this time IR value 50M ohmBefore 3days HT(IR) = value is 7000M ohm suddenly start Transformer result is Transformer not charging & HT(IR) value is down 50M ohm.
The standard abbreviation for height is ht.
Ratio of shadows = 3m:7.5m :: 1:2.5 So, the ratio of the heights (in the same order) is 1:2.5 ie Ht(Pole):Ht(Building) = 40m:Ht(Building) = 1:2.5 So Ht(Building) = 2.5*40m = 100 metres
mg zr firing order
Not if the hexagon is a regular hexagon with sides of the same length as the sides of the square.
With Hipod leakage current of any circuit (HT Distribution/ Transmission Lines) can be determine and with IR Test insulation resistance between two circuit or parts of machine is determined.
No difference. The way you use makes the difference. Normally HSFG bolts are HT only having grade 8.8 or above and tightened up to the plastic range. They cannot take the
Both are same...
lt pannel is a iow tensan pannel. lt pannel work is 240v and 440v. ht pannel is a high tensan pannel . ht pannel work is 11kv,33 kv ,66kv, 120kv
An LT panel is a device that receives power and distributes it to other devices and boards. An HT panel is the same thing except it is used for high tension cables.
The CLT has a rear side mount provision on the low clutch housing. The HT does not.
HT metering Kiosk is one which has to install between DP structure and HT panel if the distance between them was more than 15 mtrs to reduce voltage drop........
MCC panel is the bunch of motor feeders from where you can control power to connected motors, that's why it is called Motor Control Centre. PCC ( Power control centre), comprises of HT breaker's which controls power to transformers/ MCC's/ HT motors.
ht cable that means voltage level is high , it is obvious that power is going to remain same ,so if voltage rises ,current has to be lowered .since current level is less in ht cable therefore size (dia) is less compared to l.t cable , (p=v.i),lt cable current rating is more and voltage rating is less
The price of a Bridgestone Dueler HT will vary slightly depending on where one goes to purchase it but the main prices will be about one hundred and fifty dollars.
HT is High Tension - usually voltages in excess of 1kV in electronics, but in Transmission Lines it could be much higher - perhaps over 25kV.It loosely signifies that there may be an unexpected danger in the apparatus.
Frist putt of the main incomer HT side then Rack out the breaker and put the LOTO after that Discharge the cable Both side (HT/LT).