Best Answer

The wetness of the soil has no bearing on ground rods. Residential wiring requires two 8 foot long ground rods driven flush or just below the surface of the ground. One is mounted under the meter base and the other is mounted 6 feet to either side.

<<>>

The CEC (Canadian Electrical Code) requires two ten foot rods placed ten foot apart for the grounding system. The top of the rods are identified by diameter and length stamped into the rods. This is to prevent cutting the rods off if rock obstructions are encountered. If the rod will not pound into the ground any further it is bent 90 degrees and buried horizontally and again bent 90 degrees up to allow the top of the rod to protrude above the ground so as a connection can be made to it. In the new addition of the code it now allows a ground plate to be used as a grounding medium. Only one plate is required as it has more surface area than two ground rods. The plate is buried a one metre deep or a minimum of 600 mm if rock bottom is encountered.

User Avatar

Wiki User

โˆ™ 10y ago
This answer is:
User Avatar
More answers
User Avatar

Wiki User

โˆ™ 13y ago

Answer for USA, Canada and countries running a 60 Hz supply service.

A ground rod must be at least 8 feet long and is best installed straight down, so 8 feet is your depth. If you hit rock or some other obstruction, you can drive the rod at an angle up to 45 degrees. If this fails, you can bury it in a trench at least 2 feet deep.

<><><>

As always, if you are in doubt about what to do, the best advice anyone should give you is to call a licensed electrician to advise what work is needed.

Before you do any work yourself,

on electrical circuits, equipment or appliances,

always use a test meter to ensure the circuit is, in fact, de-energized.

IF YOU ARE NOT ALREADY SURE YOU CAN DO THIS JOB

SAFELY AND COMPETENTLY

REFER THIS WORK TO QUALIFIED PROFESSIONALS.

This answer is:
User Avatar

User Avatar

Wiki User

โˆ™ 14y ago

Ground rods come in 10 ft. lengths. They are to be driven in to that depth, wet ground or not. That is the Code.

This answer is:
User Avatar

Add your answer:

Earn +20 pts
Q: What is the proper grounding depth for a rod in wet land?
Write your answer...
Submit
Still have questions?
magnify glass
imp
Continue Learning about Electrical Engineering

Is a 6 foot grounding rod long enough for a new panel?

Code states that a grounding rod needs to be 8 feet long. A 6 foot rod should be okay in theory, but 8' is code.


What are the factors for selecting electrodes?

If you are talking about grounding electrodes , the types are spelled out in the electrical code book. It can be 2 eight foot rods spaced 10 foot apart. One ten foot rod and just newly accepted a grounding plate dug in to a two foot depth.


How do you properly ground an electric fence?

You need to have a grounding rod made of galvanized steel that is driven straight into the ground until only half an inch of bar is remaining above ground. The ground rod should be at least 6 feet in length. Drier land areas normally require a longer grounding rod, or more of them, spaced 10 feet apart. The ground rods themselves should be placed in [an] area[s] that are naturally permanently moist to have any effect. Then you have to run a grounding cable that is attached to the ground rod along the bottom or top of the fence (can be the top wire or bottom wire) all the way to the fence charger. This cable needs to be attached to the ground rod by ground rod clamps That grounding cable should be attached to that fence charger in order for the fence to be properly grounded. Check out the following links on tips and instructions on how to properly ground an electric fence.


How many grounding clamps are permitted on one ground rod?

As long as the clamp is of an approved type only one is needed per ground rod.


Why does your grounding meter read OL from gen to 1st ground rod and from 1st to 2nd ground rod get 28.51 ohms?

Code requires that the resistance between the two grounding electrodes be 25 ohms or less. You don't mention how deep they are or how far apart they are. THat will make a difference. Or it could be the soil they are in.You need to get the resistance down

Related questions

What is an earth rod?

A long metal rod hammered into the ground to act as a grounding post.


Is a 6 foot grounding rod long enough for a new panel?

Code states that a grounding rod needs to be 8 feet long. A 6 foot rod should be okay in theory, but 8' is code.


What are the factors for selecting electrodes?

If you are talking about grounding electrodes , the types are spelled out in the electrical code book. It can be 2 eight foot rods spaced 10 foot apart. One ten foot rod and just newly accepted a grounding plate dug in to a two foot depth.


When inspecting an air conditionerin many areas an exterior electrical disconnect is required in sight of the A condensing unit B electrical panel C electrical service entrance D grounding rod?

D, In California an unfused disconnect switch shall be installed within sight of any grounding rod as per NEC code for the following reasons: A) To definatively locate the grounding rod, B) To allow for service including troubleshooting, removal for cleaning and/or replacement of a defective grounding rod during periods of unstable atmospheric activity.


When was Rod Land created?

Rod Land was created in 1991.


When did Rod Land happen?

Rod Land happened in 1990.


How do you properly ground an electric fence?

You need to have a grounding rod made of galvanized steel that is driven straight into the ground until only half an inch of bar is remaining above ground. The ground rod should be at least 6 feet in length. Drier land areas normally require a longer grounding rod, or more of them, spaced 10 feet apart. The ground rods themselves should be placed in [an] area[s] that are naturally permanently moist to have any effect. Then you have to run a grounding cable that is attached to the ground rod along the bottom or top of the fence (can be the top wire or bottom wire) all the way to the fence charger. This cable needs to be attached to the ground rod by ground rod clamps That grounding cable should be attached to that fence charger in order for the fence to be properly grounded. Check out the following links on tips and instructions on how to properly ground an electric fence.


What is proper length of rod?

No specific clarity about rod


Electrolytic Ion Grounding Composition And Installation Location?

Ion grounding selection of cold-drawn yuan steel, with equipment outside the casting of purple copper (thickness of 0.3 ~ 0.5MM), to its excellent electrical conductivity and mechanical strength, the product has excellent anti-corrosion properties. Electrolytic Ion Grounding Electrolytic ion grounding composition โ— Connection tube Rod and rod can be connected by copper connection tube, with good effect. The contact between the rod and the rod is so tight that the driving force acts directly on the rod when the grounding rod is driven into the ground or drilled into the ground with a driving drill. There are threaded connections and non-threaded connections. โ— Drive head Made of alloy steel, it can drive the force into the ground smoothly. Ion grounding is driven into the ground under complicated geological conditions. Copper clad steel grounding rod for grounding network in the vertical grounding body, grounding in the entire lightning protection system occupies an important role, it affects the entire lightning protection system against direct lightning effect, direct lightning through the lightning rod / lightning belt and other lightning devices, and then through the grounding network into the ground, the grounding network of good or bad affect the overall effect. In foreign countries have used copper-plated grounding rod (copper clad steel grounding rod) instead of galvanized round steel, precisely because the effect of copper-plated grounding rod is several times higher than galvanized round steel. Copper clad steel grounding rod is electrolytic copper plating to the steel surface, high bonding without gaps, any bending will not produce copper layer stripping phenomenon, and because the surface of the round steel is high purity electrolytic copper, ion grounding so copper-plated grounding rod conductivity can be comparable to pure copper, is now the preferred grounding material for power engineering, petrochemical engineering, communications engineering, etc. The installation position of electrolytic ion grounding Ion grounding installation position especially when equipped with multi-level power supply lightning protection is very important, if not carefully considered, may be selected according to the technical requirements of the ion grounding is not very good protection. Both a waste of money. And left a lightning accident potential. This is due to when the overvoltage wave transmission along the cable, the protected equipment and the power supply lightning protection device between the energy reflection. This reflection phenomenon and the characteristics of the power supply lightning protector at all levels, the characteristics of the equipment being protected and the characteristics of the cable between them. It can cause overvoltage on the protected equipment that far exceeds the residual voltage on the power surge protector, and may be fed back into the power system to produce a bad effect. We are a professional grounding equipment manufacturer, if you are interested in this, please contactโ€‚Sichuan Sunlight Intelligent Co.


What is needed to ground a 550 gallon above ground gas storage tank?

A 6 ft to 8 ft grounding rod should be enough. Pound that down into the ground. run a 10 to 12 gauge grounding wire from the rod to the tank and clamp it tight.


How many grounding clamps are permitted on one ground rod?

As long as the clamp is of an approved type only one is needed per ground rod.


How does the lightening rod work?

Very well -If it is elevated high enough to provide the first point of grounding the excess electrons and lighting strikes in the area above a building and the rod location.