Connect incoming power to the line side of GFCI outlet and plug Jacuzzi into the outlet. Must be on a dedicated circuit. If it has a pump and heater then each one must be on dedicated GFCI protected circuit.
I assume you are hard wiring it and not plugging it in. The power coming into the GFCI outlet connects to the line side of the GFCI outlet. If you want the outdoor timer protected by the GFCI then connect the wire going to the timer to the load side of the outlet. If you do not want the timer protected then connect it to the line side. On the back of the GFCI if you look closely you will see Line & Load marked on the back.
Not if the GFCI breaker is supplying the circuit you are wanting to put the GFCI receptacle into.
You use the correct size breaker that matches the wiring. The correct amperage will be listed in the owners manual for the tub.
Your question is a bit vague, but let's try a two part answer. If you have a GFCI breaker in an electric panel you should only have one connection at the breaker, but the breaker will protect all devices on the circuit. If you are talking about a GFCI outlet, they are equipped to extend the GFCI protection to other non-GFCI outlets by using the proper "output" connection on the GFCI.
Deoends on code you are governed by. In USA, a GFCI outlet or a circuit controlled by a GFCI circuit breaker would be required.
no it will only decrease the current carrying capability
I assume you are hard wiring it and not plugging it in. The power coming into the GFCI outlet connects to the line side of the GFCI outlet. If you want the outdoor timer protected by the GFCI then connect the wire going to the timer to the load side of the outlet. If you do not want the timer protected then connect it to the line side. On the back of the GFCI if you look closely you will see Line & Load marked on the back.
A jacuzzi suite is a suite that has a jacuzzi tub.
Assume this is a ground fault circuit interrupter (GFCI) outlet. The GFCI looks for current that is flowing to ground, in a manner that could result in electrical shock to a user. The appliance that is being plugged in could be defective, the wiring connected to the load side of the GFCI may be incorrect, or the GFCI outlet could be defective. Try using another appliance. If the GFCI holds, the first appliance is most likely the cause.
Not if the GFCI breaker is supplying the circuit you are wanting to put the GFCI receptacle into.
Since GFCI's are more expensive, you wouldn't want to use them in any place where they are not required. In many old homes, GFCI's are sometimes used for outlets in bedrooms and living rooms where proper grounding is necessary (for computers, TV's, other electronics), but not available because of the age of the wiring. You would also want to avoid cramming a GFCI into a box that is too small to accommodate the bulkier GFCI outlet. You should first replace the box to a larger one.
Jacuzzi's population is 4,907.
It is named after its inventor.
the same, 'un jacuzzi' (masc.)the same, 'un jacuzzi' (masc.)
No, it must be on a dedicated circuit of it's own. It must be on AWG 12/2 wire with 20 amp breaker. It also must be protected with a GFCI outlet.
Yes you can. Lots of blow dryers have GFCI protection built in.
In a word NO, that will not cause either GFCI to trip. The correct term is GFCI (Ground Fault Circuit Interrupter)