There is no bonding jumper wire required on a 200 amp service panel. The meter stack is metallic and is continuous from the mast head down to the distribution panel.

If you are talking about the ground wire for a 200 amp panel it requires a #6 bare copper conductor that connects the grounding rod or plate to the neutral point in the distribution panel.

Assuming the answer above is an example of a service, where the meter is stacked above the first service disconnect and is mated to this panel by a threaded hub. However if your meter were to be mounted beside your first service disconnect and a metal nipple with lock nuts were used for raceway. You would be required to have a bonding jumper on that nipple sized according to NEC Table 250.122. So for 200 amp that would be #6 copper or #4 aluminum.

User Avatar

Wiki User

10y ago
This answer is:
User Avatar

Add your answer:

Earn +20 pts
Q: What size bonding jumper for 200 amp service panel?
Write your answer...
Submit
Still have questions?
magnify glass
imp
Related questions

What size copper main bonding jumper is required based on the service entrance conductors being rated at 250 kcmil thwn-thnn copper?

Based on NEC 250.66- #2 copper or 1/0 aluminum.


What size grounding wire do you use as the 4th wire running in your conduit from your 200 amp meter box to your 200amp service panel this is the ground wire from box to box?

You do not use a ground wire in the connection from the meter base to the distribution panel. A bonding wire may be required if the service is using PVC conduit.


What is the minimum service size for a 225amp residential service?

A 200 amp service panel with a 60 amp sub-panel.


What is the minimum size breaker panel for a home's main service?

50 amps


What is the minimum size breaker panel required for a homes main service?

50 amps


What size service cable for 100 amp main panel 100 feet away?

20Sqmm


What size neutral wire for 200 amp service panel?

AWG # 3/0 copper.


What is the largest sub panel you can install off from a 60 amp main panel fed by 100 amp service?

If what you state in this question is accurate this is an illegal installation. A 100 amp service can not have any equipment connected to it less that that of the service size. The 60 amp main panel must be a 100 amp panel to be a legal installation.


Is a horse a highest jumper in the world?

In comparison to its size, the horse is not the highest jumper in the world. Proportionally, it is the grasshopper.


Which animal is the best jumper not relative to body size?

The animal that is the best jumper and not relative to body size is the flea. However, the kangaroo is also known for its jumping abilities.


Ground wire size for 200?

A 200 amp service panel will require a # 4 bare copper ground wire.


What is the average size for service panel for a 1200sqft house built in 1995?

It was probably a 150 amp service back in 1995. Todays services are usually 200 amps.