answersLogoWhite

0


Best Answer

Need to know what size service is going to be installed at the end of the run.

User Avatar

Wiki User

14y ago
This answer is:
User Avatar

Add your answer:

Earn +20 pts
Q: What size conductors are needed to run a 400 foot residential underground electric service?
Write your answer...
Submit
Still have questions?
magnify glass
imp
Continue Learning about Electrical Engineering

What is the cable between the service panel and electric meter called?

Whether you have an overhead or underground feed, that section of the installation is referred to as Service Entrance Conductors. On an overhead installation, it includes the conductors on BOTH sides of the meter, from the service drop conductors (attached at the service head) to the service equipment LINE terminals. On an underground installation, it refers only to the conductors between the meter's LOAD side and the service equipment LINE terminals. The conductors on the LINE side of the meter come from a distribution transformer and are unbroken between the transformer and your meter.


Can triplex be run in underground conduit?

YesIn Canada the answer is no. Triplex is an aerial rated set of conductors that are used to bring the voltage from the utilities pole to the service drop at the home. Triplex consists of two ungrounded conductors wrapped around a neutral steel supported conductor. These conductors can be used on higher current capacities due to the direct cooling of the conductors by the surrounding air. This is why you will see a service drop of number 6 conductors supplying a 100 amp service. For a three phase four wire system quadplex is used to make three phase connections to commercial and industrial services.


What are feeders in power system?

"Feeders" are conductors which carry electric power from the service equipment (or generator switchboard) to the overcurrent devices for groups of branch circuits or load centers supplying various loads.


What is the minimum size neutral for three sets of parallel 500kcm copper conductors for a service?

On large service entrance services the neutral can be reduced. The amperage of the service and the voltage of the service and the insulation factor of the 500 MCM conductors need to be stated to answer this question correctly.


How much does electricity cost per kilowatt hour in Knoxville TN?

Residential Electric RateCost per Kilowatt Hour (Cents) as of 9/1/11 Single Family Dwelling8.850Basic Service$10.00

Related questions

What is a service lateral conductor?

service lateral conductors are the underground conductors between the utility electric supply system and the service point, basically the cables that bring power from the transformer to the power meter in an underground service


What size conductors are needed to run a 650 foot residential underground electric service for a 200 amp service?

A 350 MCM copper conductor will limit the voltage drop to 3% or less when supplying 200 amps for 650 feet on a 240 volt system.


What is the cable between the service panel and electric meter called?

Whether you have an overhead or underground feed, that section of the installation is referred to as Service Entrance Conductors. On an overhead installation, it includes the conductors on BOTH sides of the meter, from the service drop conductors (attached at the service head) to the service equipment LINE terminals. On an underground installation, it refers only to the conductors between the meter's LOAD side and the service equipment LINE terminals. The conductors on the LINE side of the meter come from a distribution transformer and are unbroken between the transformer and your meter.


What is the wire that runs from the electric meter to the breaker box called?

Service Entrance Conductors.


Can the load wires in an electrical service panel exit from the same end as the service cable and meet code?

Per the 2011 National Electric Code, Art 230 Services:230.7 states:"Conductors other than service conductors shall not be installed in the same raceway or service cable."Exception #1: Grounding conductors and bonding jumpers.Exception #2: Load management control conductors having overcurrent protection.


What is maximum amps for residential exterior light?

The maximum amps for residential exterior light have different steps. One is having the service equipment like the main panel, entrance conductors, and meter base also having guidelines and code summary.


What percentage of US has Residential Phone Service?

75% of US has Residential Phone Service.


Can triplex be run in underground conduit?

YesIn Canada the answer is no. Triplex is an aerial rated set of conductors that are used to bring the voltage from the utilities pole to the service drop at the home. Triplex consists of two ungrounded conductors wrapped around a neutral steel supported conductor. These conductors can be used on higher current capacities due to the direct cooling of the conductors by the surrounding air. This is why you will see a service drop of number 6 conductors supplying a 100 amp service. For a three phase four wire system quadplex is used to make three phase connections to commercial and industrial services.


What size service conductors do you need for a single phase 600 amp commercial panel?

The size of wire for service entrance conductors for a 400 amp 3 phase service could be 500 MCM copper. This is very large size wire and difficult to bend and shape, to connect to terminals in the main disconnect and distribution panel. This problem is solved by using parallel conductors or on higher ampacities triple conductors. Using parallel conductors the wire size would be three ought (3/0) copper.


What type of compression fittings can be used on an underground copper service pipe?

I am a Plumbing/HVAC Contractor and the type of fitting I always used for underground copper service pipe has been 3/4" (standard size for residential) brass flared fittings. A flared connection is a tight, secure connection guaranteed not to leak.


Where can I find good Residential Phone Service in Boston?

Verizon offers great Residential Phone Service in Boston


What is the underground depth for pge electric service lines on private residential property?

It's best to call Diggers Hotline (free) so they can mark the location of the various underground utility lines. They'll mark the locations (but not the depth). The depth of utility lines varies, but could be 18 inches. Natural gas lines are usually plastic and at higher pressure than at your home appliance (regulated by the gas meter).