This is a voltage drop question. A voltage value needs to be stated. Assuming that the 200 amp panel is a single phase 120/240 volt sub panel. A #1 copper conductor will limit the voltage drop to 3% or less when supplying 100 amps for 200 feet on a 240 volt system.

User Avatar

Wiki User

โˆ™ 2011-09-25 00:57:13
This answer is:
User Avatar
Study guides

Physics

20 cards

What type of circuit in which all parts are connected in a single loop

What angle is between 90 and 180

What condition has symptoms that include ringing buzzing or roaring in the ears or head

What is the transfer of energy as electromagnetic waves called

โžก๏ธ
See all cards
3.85
โ˜†โ˜…โ˜†โ˜…โ˜†โ˜…โ˜†โ˜…โ˜†โ˜…
26 Reviews

Add your answer:

Earn +20 pts
Q: What size wire for 100 amp panel 200 feet away from a 200 amp service?
Write your answer...
Submit
Still have questions?
magnify glass
imp
Related questions

What size service cable for 100 amp main panel 100 feet away?

20Sqmm


What gauge wire to use for direct burial for a garage that is 400 feet from your house?

Depends on the size of the sub-panel in that garage. If you are installing a 60 amp sub-panel 400 feet away from the main service panel then use AWG # 4.


What size wire do you need to run overhead to a 50 amp service five hundred feet away?

For that distance I would run AWG # 3 copper and install a sub-panel.


What size wire do you need from a 200 amp panel to a 150 amp sub panel about 80 feet away?

1/0 copper


What size wire to run 250 feet away 60 amp sub panel?

AWG # 4


What is the minimum service size for a 225amp residential service?

A 200 amp service panel with a 60 amp sub-panel.


What size copper wire do you need for 50 amp sub panel about 325 feet away?

You will need to run AWG #4.


400 feet run for 100 amp service what size wire?

Assuming the voltage is 240 volts, the wire size for a 100 amp panel at the end of 400 feet and holding the voltage drop to 3 %, the wire will be 3/0 in size.


What size underground service entry cable needed for 100 amp sub panel 600 feet from main?

AWG 2/0 copper.


What size underground wire do you need from a 200 amp panel to a 100 amp panel 150 feet away?

Need to know what the load amperage is on the 100 amp panel. If interested, open discuss question page.


What size wire do you need for 50 amp sub panel about 100 feet away?

AWG #6 will work fine at 100 feet with only a 2% drop in voltage which is acceptable.


What wire size is used to make service connection from a 200 amp service panel to a 40 amp service panel 150 feet away?

8 AWG copper is rated for 40 amps. Over 150 ft, at maximum current, the voltage drop would be about 3.76 volts. Using 6 AWG would have a voltage drop of 2.36 volts with the same 40 amps.