what size wire would be required for an ak012 with a power supply of 208/240-3-60 hz

User Avatar

Wiki User

6y ago
This answer is:
User Avatar
More answers
User Avatar

Wiki User

12y ago

#6 AWG

This answer is:
User Avatar

Add your answer:

Earn +20 pts
Q: What size wire for a 45 AMP fuse?
Write your answer...
Submit
Still have questions?
magnify glass
imp
Related questions

What size wire cable and fuse for a 9.8KW shower?

7.2kW shower = 32 Amp fuse = 6 mm2 cable size7.5kW shower = 40 Amp fuse = 10 mm2 cable size8.5kW shower = 40 Amp fuse = 10 mm2 cable size9.5kW shower = 40/45 Amp fuse = 10 mm2 cable size10.5kW shower = 45 Amp fuse = 16mm2 cable size


What size wire required to run 5 amp 220v?

45


What size fuse for a 200 watt amp?

assuming this is a 12 volt system....45 amps.


What size wire for a 40 amp breaker to a welder?

A #8 aluminium wire with an insulation factor of 90 degrees C is rated at 45 amps.


Can 50 Amp breaker replace 45 Amp breaker?

Both a 45 amp and 50 amp breaker would require 6 AWG wire. So if you have 6 AWG wire and any devices like an outlet are rated at 50 amps or greater you are okay.


Your shower keeps tripping it is 40 amp fuse it requires 45 amp how do you change it?

The question does not give enough details to answer


What is the size wire for 45 amp at 13.8 volts?

6 AWG. It is the amps that matter most, but there are other elements in that a maximum voltage may be specified as it relates to the insulation on the wire. In an auto the wire is usually stranded rather than solid.


What size wire is required to run 40 amp 220v in Canada?

Number 8. Wire <<>> A #8 copper conductor with an insulation factor of 75 and 90 degrees C are both rated at 45 amps.


Can I use a 30 amp fuse instead of a 40?

This is not a good idea to do. Sometimes just that little bit of extra current that the 45 amp fuse will allow to reach the 40 amp load might be enough to destroy the device.


What size wire for a 40 amp breaker?

A 40 amp breaker is used in conjunction with AWG # 8 copper wire. The black and red wires are connected to the breaker. The ground wire is connected to the ground bar and the white wire is connected to the neutral bar.


What size cable is needed to wire a cook stove?

Answer for USA, Canada and countries running a 60 Hertz supply service.With out knowing the specifics of the stove, a home is usually prewired with a #8 wire which has a rating of 45 amps. This wire is protected with a two pole 40 amp breaker.


Could you use a 12gauge wire for a 25 amp breaker single pole?

No a #12 wire is only rated for 20 amps. The 40 amp breaker will not protect the #12 wire. A 40 amp breaker should have a #8 wire connected to it which is rated at 45 amps. The only time that a breaker is allowed to be bigger that the wire size rating according to the electrical code is when a motor is connected to the breaker. This is to stop the 300 percent inrush of the motor full load amps from nuisance tripping a smaller sized breaker.