answersLogoWhite

0


Best Answer

Dryer plug three to four

Open up the electrical access panel on the back of the dryer. You will see a terminal block with three wires going into it from the plug cord assembly. A red and black and white are now connected to the terminal strip. Look at the position and colours of the existing 3 prong cord and how it is connected. Make a diagram. Coloured wires on the outside terminals white in the center. From the center wire terminal you will see a jumper strap that goes to the frame of the dryer. When installing the four prong plug this jumper is removed completely. The kit should have with it a grounding lug that connects to where the removed grounding strip attached to the frame of the dryer. This is the attachment point for the fourth green ground wire from the new dryer cord assembly.

<<>>

Make certain that it's wired properly;

White=Neutral

Green or Bare Copper=Ground

Black, Red = Hot

there should be 2 "Hot" wires in a 4 wire 240 V circuit, one Neutral and one Ground.

Make certain that you study the outlet to determine where the wires go. If the breaker keeps tripping, something is wired wrong.

If you cannot easily find the problem, contact a local electrician or handyman for help. (assuming that your state allows a handyman to perform minor electrical repair)

Make sure you also remove the jumper between the ground and the neutral on the dryer.

User Avatar

Wiki User

14y ago
This answer is:
User Avatar

Add your answer:

Earn +20 pts
Q: You changed 3 wire to a 4 wire on a dryer and keeps blowing circuit breaker?
Write your answer...
Submit
Still have questions?
magnify glass
imp
Continue Learning about Natural Sciences

What would happen if a 240V breaker was on and someone attempted to turn on the clothes dryer?

Don't understand this question. If the breaker is on, then the dryer would function normally, if the breaker your are referring to is the one for the dryer. If the breaker is off then no function. A dryer runs on 220.


Why your electric dryer makes breaker hot?

If the circuit breaker to a dryer, or to any load, keeps getting hot and trips the breaker, then either the load is pulling too much current or there is a loose connection in the breaker or breaker panel. Either condition must be fixed to reduce the risk of fire.


Can you use a 20 amp circuit breaker for an electric dryer?

If you are referring to a cloths dryer, the answer depends on the requirements of the dryer. Most dryers require AWG#10 wire with a 30 amp fuse. If the wiring is AWG#12 then use a 20 amp breaker but never use it on AWG#10 which requires a 30 amp breaker. If you are referring to a hair dryer then yes a 20 amp breaker is fine.


Where is the double 30 amp breaker in an electric dryer?

It should be in the main circuit panel. If the dryer was added at some point there may be a separate box just for the dryer either beside the main panel or at the dryer plug. It is not in the dryer itself.


Why does the furnace kick out the breaker?

The only reason the dryer breaker will trip is it senses an overload or a short circuit on the circuit. To test this unplug the dryer and see if the breaker will stay latched. If it does then the wiring to the receptacle is not at fault. If you want to delve further into the problem, leave the dryer unplugged and remove the inspection panel at the back of the dryer and check the connections. Sometimes the screw terminals become loose and corroded and cause the dryer to draw more current. To compensate for the higher resistance at the faulty terminals the dryer will try to draw more current that the breaker will allow. If everything looks good after trying both of these things it is time for a repairman to come in and look at the dryer itself, as the fault is probably an internal problem within the dryer body.

Related questions

What would happen if a 240V breaker was on and someone attempted to turn on the clothes dryer?

Don't understand this question. If the breaker is on, then the dryer would function normally, if the breaker your are referring to is the one for the dryer. If the breaker is off then no function. A dryer runs on 220.


Why does your main circuit breaker trip when your dryer runs 15 minutes Is it because your vent needs to be cleaned?

Could be but you could also have a weak breaker that will no longer hold the load of your dryer. That is if your talking about your dryer breaker tripping. If your "main breaker" is tripping you have a different problem. Call an electrician in that case. A plugged up dryer shouldn't be tripping your main


Why your electric dryer makes breaker hot?

If the circuit breaker to a dryer, or to any load, keeps getting hot and trips the breaker, then either the load is pulling too much current or there is a loose connection in the breaker or breaker panel. Either condition must be fixed to reduce the risk of fire.


What size amp circuit breaker should be used for a gas dryer?

Typical residential electric dryers are on 30 amp circuits, which means 10 gage copper wire. The circuit breaker should match the dryer cord rating, generally 30 amps.


Can you use a 20 amp circuit breaker for an electric dryer?

If you are referring to a cloths dryer, the answer depends on the requirements of the dryer. Most dryers require AWG#10 wire with a 30 amp fuse. If the wiring is AWG#12 then use a 20 amp breaker but never use it on AWG#10 which requires a 30 amp breaker. If you are referring to a hair dryer then yes a 20 amp breaker is fine.


What can you do if you're newly installed dryer keeps tripping the electrical panel repeatadly and it also trips the GFI in the Garage at the same time?

If the GFI that is tripping is a different circuit, there is electrical leakage between the circuit the GFI is controlling, and the dryer circuit. It is possible that there is some cross wiring in the electrical box. I would strongly recommend getting a licensed electrician to look at it, preferably before you have a fire. If the GFI is the same circuit as the one where the dryer is plugged in, you might want to have the dryer checked for leakage to ground. You should also check the dryer circuit's rating against the rating of the breaker in its circuit. A dryer typically takes 30A on usually a single two-gang breaker; if you have a larger dryer that pulls, say, 45A, a 30A breaker will always pop. It sounds to me like a bad electrician has, instead of buying a proper two-gang 30-A breaker, installed your dryer across two circuits, one being the garage GFI circuit; the dryer, because it pulls 220V, pulls an unbalanced load across the GFI and triggers it, and the other circuit breaker is triggered because it loses the extra power provided through the GFI. I cannot emphasize this enough: get this checked out and fixed. Now. Before you get a house fire.


Where is the double 30 amp breaker in an electric dryer?

It should be in the main circuit panel. If the dryer was added at some point there may be a separate box just for the dryer either beside the main panel or at the dryer plug. It is not in the dryer itself.


Why does the furnace kick out the breaker?

The only reason the dryer breaker will trip is it senses an overload or a short circuit on the circuit. To test this unplug the dryer and see if the breaker will stay latched. If it does then the wiring to the receptacle is not at fault. If you want to delve further into the problem, leave the dryer unplugged and remove the inspection panel at the back of the dryer and check the connections. Sometimes the screw terminals become loose and corroded and cause the dryer to draw more current. To compensate for the higher resistance at the faulty terminals the dryer will try to draw more current that the breaker will allow. If everything looks good after trying both of these things it is time for a repairman to come in and look at the dryer itself, as the fault is probably an internal problem within the dryer body.


Can one unit pay for the other units use of electricy if their dryer is hook up to the first units circuit breaker?

Yeah unless the dryer in their unit has a meter connected to it.


Can you hook up a 240V circuit in series to a dryer and electric range?

The short answer is no. First off I assume you mean "can you have a dryer and an electric range on the same circuit?" (If they were actually wired in series, then you couldn't use your range if the dryer was off) In theory you could have them on the same circuit you just need to make sure that the wiring and the circuit they are on can handle the number of amps the two of them could draw together. If your breaker isn't big enough, it kill the power to the range while you are cooking dinner. If the wiring can't handle the load, then there is a fire risk. A dryer is usually on a 30amp circuit and a range is usually on a 50amp circuit, so to have them together would require an 80amp circuit, which will be difficult to find a breaker and wiring for.


If you install a 30A 240V GFI breaker will this be ok or will the cycles the dryer has prematurely fail the breaker?

I suspect you mean GFIC breaker. The dryer will not cause the breaker to fail.


Why does my 1875 watts hairdryer keep blowing out the lights?

If you are operating on a standard 120 volt system, 1875 watts will draw 15.625 amps. A standard fuse or circuit breaker is 15 amps. You are drawing more current than the wiring was designed to provide. The breaker or fuse stops that before you burn down the house. You need a smaller dryer, or bigger wiring.