By considering the safety factor, it is better to use 6mm2 wire.

Another AnswerIn the US, use 8 Ga, 3 conductor copper wire + ground for typical applications.
User Avatar

Wiki User

15y ago

What else can I help you with?

Related Questions

How do you install a new range receptacle?

A new outlet (running new wire) or replacing an old one (wires already there)? Shut off the Power to that Receptical, diconnect the receptical, and reconnect the New receptical using the Wires from the one you replaced. Then turn the power back on and Test it with a Tester!


Can you use 6-3 NM wire and 50 amp breakers and 50 amp range cord for a 40 amp max load range?

No, it is not advisable to use a 50 amp breaker with a 40 amp-rated appliance like a range. You should match the breaker size to the appliance requirements. In this case, you should use a 40 amp breaker, 8-3 NM wire, and a 40 amp range cord for the 40 amp max load range.


What is cooking range outlet?

It is a receptacle outlet wired into a home with the capacity to handle the amperage rating of the range. The cord on the range plugs into this receptacle to receive its power supply so that the range can operate.


Where can you find a diagram for installing a new range with a four prong cable if the range you are replacing only has a three prong cable?

Answer for USA, Canada and countries running a 60 Hz supply service.Range receptacle three to fourFirst thing to do is turn off the breaker to the range. Look in the back of the range receptacle box that is in the wall. The three wires coming in should have a bare ground wire in the cable set. It wasn't brought to the receptacle because there was no place for it on the three wire receptacle. If you find it back there under a screw terminal just add another short piece of wire under the screw and then connect the other end of the short wire to the new ground terminal on the new four position receptacle. The wire should be equal in size to the size of the wire that exists around the ground terminal now. If the house is so old that the range cable did not have a ground wire in it the code allows a separate green ground #10 wire to be taken from the breaker panel box to the existing range receptacle. This wire is to be bonded on each end. At the panel end to the ground buss and at the receptacle end around the ground screw at the back of the box unbroken and then to the new four position receptacle ground lug.Before you do any work yourself,on electrical circuits, equipment or appliancesalways use a test meter to ensure the circuit is, in fact, de-energized.IF YOU ARE NOT ALREADY SURE YOU CAN DO THIS JOBSAFELY AND COMPETENTLYREFER THIS WORK TO QUALIFIED PROFESSIONALS.


What is the purpose of a range receptacle and how does it function in a kitchen appliance?

A range receptacle is used to provide power to an electric range or stove in a kitchen. It functions by connecting the appliance to the electrical wiring in the kitchen, allowing it to receive the necessary electricity to operate.


What is the recommended range breaker size for a circuit breaker in a residential electrical panel?

The recommended range breaker size for a circuit breaker in a residential electrical panel is typically between 15 to 20 amps.


What size breaker should be used for an electric range?

A 40-50 amp breaker is typically used for an electric range.


What is the recommended amperage for a breaker to use with a range: 40 or 50 amp?

The recommended amperage for a breaker to use with a range is typically 50 amps.


What is the range of a circuit breaker?

The range of a circuit breaker refers to the maximum amount of electrical current it can safely handle before tripping and shutting off the circuit. This range is typically measured in amperes (A) and varies depending on the specific type and rating of the circuit breaker.


What does the range mean on a breaker box?

The range on a breaker box refers to the maximum amount of electrical current that the circuit breaker can handle before it trips and shuts off power to the circuit. It is important to not exceed the range to prevent electrical hazards and damage to the electrical system.


What is the function of the breaker for an electric range?

The function of the breaker for an electric range is to protect the appliance and the electrical circuit from overloading or short circuits by interrupting the flow of electricity when there is a problem.