What is the largest size of sub-panel and wire that should be used from a 200 amp service for a basement apartment?

Sorry, it depends ...

Literally, it is a question of which manufacturer's load center the sub-panel is being derived from.

Some manufacturers, Square D [QO line] for example, have a 200 amp breaker, QO2200BB, that can be installed in the panel as a branch breaker. This would theoretically allow you to install a 200 amp sub-panel in the apartment.

You need to calculate the load for the apartment and size your branch breaker accordingly.

Remember that the neutral has to be isolated from the ground buss in the sub-panel.

<><><>

As always, if you are in doubt about what to do, the best advice anyone should give you is to call a licensed electrician to advise what work is needed.

Before you do any work yourself,

on electrical circuits, equipment or appliances,

always use a test meter to ensure the circuit is, in fact, de-energized.

IF YOU ARE NOT ALREADY SURE YOU CAN DO THIS JOB

SAFELY AND COMPETENTLY

REFER THIS WORK TO QUALIFIED PROFESSIONALS.

User Avatar

Wiki User

14y ago
This answer is:
User Avatar
More answers
User Avatar

Wiki User

11y ago

I'm assuming single phase 3 wire so it would be #3 R90 Aluminum cable or #4 R90 Copper Cable

This answer is:
User Avatar

Add your answer:

Earn +20 pts
Q: What is the largest size of sub-panel and wire that should be used from a 200A service for a basement apartment?
Write your answer...
Submit
Still have questions?
magnify glass
imp
Continue Learning about Natural Sciences

How do you hook up a 15 amp breaker to a 60 amp box?

If by "60 amp box" you mean a 60-amp service panel (circuit breakers or fuses), you would generally get a 60-A panel that has several slots designed to accept a variety of compatible breakers, from 15A to 60A. If you have a "box" with no breakers, you would need another "subpanel", with wires from the 60A box to the new subpanel, and install one or more 15A breakers in the subpanel. If you don't need more than one breaker, you might also simply use a 15A disconnect panel with a single breaker in it.


Can you use aluminum service cable to feed a sub panel?

Yes, as long as it has the necessary ampacity for the load and is properly fastened at each terminal. For example, we have a 4/0 aluminum cable feeding our 200 A subpanel 120 feet away.


Can you run an additional breaker panel parallel to the existing one?

It is not in parallel. You put a breaker in existing panel and use that to feed the subpanel. The Amperage of this subfeed breaker should match the rating of the new panel. For example a 100A breaker might be typical. Remember that ground and neutral are only "bonded" at the main panel. Usually a subpanel has a means to separate the neutral and ground in a subpanel. Be careful since everything about doing this is dangerous.Another AnswerYes, you can have two breaker panels in parallel. If you had a 100 amp panel on a 200 amp service (or increase the size of the service, check with your power company on the size of your service, you could add a second 100 amp panel in parallel with the first. You can have up to 6 disconnects per service, but they must be located adjacent to each other or in the same enclosure. So either install the second panel beside the first or a 100 amp disconnect beside the first panel and feed out of the disconnect to the new panel located where you need it.


In a home circuit are the neutral and ground bare wires always connected?

They are always connected, but at one and only one place, the service entrance. For instance, if you are adding a subpanel to an existing house, the subpanel will probably come with the ground bus and the neutral bus tied together with a special bonding screw. To be legal, you must remove this screw, isolating the neutral from ground. The house's main panel still has the bonding screw or jumper in place, and remains the only place the connection is made.


Which is the largest ambulance service in the world?

EDHI Ambulance Service,, more than 2000 Ambulances as per record 2 years back

Related questions

Where can rent apartment in Baltics?

You can rent apartment in Baltics through online service: http://bookapartment.eu


How do I find a low income apartment in brooklyn?

I would suggest using an apartment locator service. Apartment locators find apartments for you and pay you for it.


Do you need a broker license to operate a apartment locating service?

no!


Do you need a grounding rod at a subpanel on a detached building?

Yes. The panel must be grounded with its own grounding rod. The ground will not be provided with the feeders to the panel, these will only contain your phase wires and neutral. Also make sure that any subpanel installed does not have the neutral bonded to ground. This should only be done at the main panel where the electrical utility service is connected.


Who do residents complain to about poor service in apartment servicing?

They can complain to the apartment management staff. If this produces no results then they can complain to the Code Enforcement Bureau.


What services does Basement Technologies offer?

The company Basement Technologies provides basemnt waterproofing services. They also offer fundation wall replacements and provide their service in the US and Canada.


Is it unsafe to have 60A service going into a new electrical box designed for 100A?

Its not recommended because your new main breaker will allow up to 100 amps and your old wire can only safely handle 60amps. If you put a 60amp main breaker in the new box, that would be acceptable. No, it is perfectly safe. Because the box is overrated, there is no problem. If the box is the main panel, and not a subpanel, install a 60A main breaker so you cannot overload your service. If it is a subpanel this 60A breaker should be in the main panel.


How do you hook up a 15 amp breaker to a 60 amp box?

If by "60 amp box" you mean a 60-amp service panel (circuit breakers or fuses), you would generally get a 60-A panel that has several slots designed to accept a variety of compatible breakers, from 15A to 60A. If you have a "box" with no breakers, you would need another "subpanel", with wires from the 60A box to the new subpanel, and install one or more 15A breakers in the subpanel. If you don't need more than one breaker, you might also simply use a 15A disconnect panel with a single breaker in it.


Where could one find serviced apartments in the US?

One could find serviced apartments in the U.S. on the following websites: Apartment Service, BridgeStreet Residences, and Move and Stay. Apartment Service is the highest ranking of the three websites.


What is needed to put a 240V outlet in a garage very close to a circuit panel with NO open slots available?

an electrician. you may have to upgrade your service if not you will need an additional box to accomodate the new breaker Assuming you meet local code and license requirements, and know how to shut things off while you're working: The full circuit panel may be a service panel or a sub-panel with main lugs only (no main disconnect). If it's a sub-panel you need to find the breaker that feeds it from the service panel (if any) to make sure it has enough ampacity to run your 220 appliance on top of whatever is there already. Assuming the breaker and feeder conductors will support the additional load, you can add another subpanel (or replace the existing subpanel with a larger one). If not, you can wire a completely new feeder from the service panel to a new subpanel (or just a 220 disconnect/fuse for your new appliance). If the wiring is old, the minimum disturbance to the existing wiring is recommended: put in a new circuit from the service panel. Some subpanels include extra main lug terminals for feeding other subpanels. Otherwise you can either add another tap to the main lugs and run them to the new subpanel, or else replace two of the existing breakers with a 2-pole breaker that feeds the new subpanel. Put the new 220 circuit into the new panel along with the two old circuits removed from the old full panel to make room for the subfeed breakers.


Can I get high speed cable internet service in an apartment?

You can get cable Internet in an apartment. Just call your cable company and tell them what you want. They'll fix you up.