2/0 if copper is used; 4/0 if aluminum is used. The neutral and ground are usually smaller.
2/0 is only rated for 185 amps.
3/0 copper is rated for 210 amps, 250 MCM is rated at 215 amps if aluminum is used.
A three-phase meter can be used for single phase while the reverse is not the case.
is 3 phase Meter electicity to for the measurement of elektricity 3 phase.
Phasing, or the number of phases in an electrical system has nothing to do with the voltage. A single phase and three phase supply could have a voltage supply of any given voltage from virtually 0 to infinity. Most single phase power supplies in the US are 120/208-240 volt. Three phase power supplies are typically 120/208 to 277/480 volt.
The reverse running of a three phase meter is possible when one of the meter's two potential coils fails. This is a problem found typically on a Delta service. A three phase meter in this condition is damaged and will report lower energy use than actual.
A current transformer has to have the same ratio as the meter that it drives. Full scale deflection on the meter is 5 amps which equals the maximum allowed current on the phase that it is reading. A different ratio on the CT to meter would show an erroneous reading on the meter depending on the ratio of the connected CT. To keep costs down the meter is common to all three phases and is read by connecting the meter to the phase CT through a three position switch.
One feeder will do the job. The definition of a feeder in the electrical trade is a set of conductors that supply a source to a load. The sizing of the feeders will depend on what the load current is. The wire count of the feeder will be dependant upon whether the load is single phase or three phase.
A three-phase meter can be used for single phase while the reverse is not the case.
is 3 phase Meter electicity to for the measurement of elektricity 3 phase.
No, a single phase kWh meter is designed to measure the energy consumption of single phase loads only. To measure the energy consumption of a three phase load, you would need a three phase kWh meter specifically designed for that purpose. Using a single phase meter for a three phase load would not provide accurate energy consumption readings.
Phasing, or the number of phases in an electrical system has nothing to do with the voltage. A single phase and three phase supply could have a voltage supply of any given voltage from virtually 0 to infinity. Most single phase power supplies in the US are 120/208-240 volt. Three phase power supplies are typically 120/208 to 277/480 volt.
1.2 meter
A 3-phase meter measures the sum of the power in the three phases, so if power is drawn on one phase only it will still be correctly measured.
Your question is rather confusing, as you do not specify what you mean by 'panels'. Your reference to a 'two-phase' supply is also confusing because two-phase supplies are an archaic precursor to 'three-phase' supplies, and it's unlikely you'll come across any two-phase supplies anywhere these days!
As with any IDMT relay the higher the fault current the quicker the trip time.
The reverse running of a three phase meter is possible when one of the meter's two potential coils fails. This is a problem found typically on a Delta service. A three phase meter in this condition is damaged and will report lower energy use than actual.
yes they must be protected individually
Head stud tension on Isuzu G200 Phase 1. 29ft/lbs or 39 newton meter Phase 2. 54ft/lbs or 73 newton meter Phase 3. 72ft/lbs or 98 newton meter