That depends on the size of the welder.

A 240 V welder that is recommended to operate on a 30 Amp circuit should be wired with a 10 AWG wire.

User Avatar

Wiki User

14y ago

What else can I help you with?

Continue Learning about Natural Sciences
Related Questions

What is the maximum amperage rating for a 15 amp extension cord?

The maximum amperage rating for a 15 amp extension cord is 15 amps.


How many amps will a 12 3 extension cord handle?

A #12 copper wire is rated at 20 amps. On an extension cord, unless it has user installed ends, the rating of the three blade cap is only 15 amps. Either way the extension cord should only be loaded up to 80% of the wire rating. 20 x .8 = 16, 15 x .8 = 12.


What is the amp rating of 14-3 extension cord?

A #12 copper wire is rated at 20 amps. On an extension cord, unless it has user installed ends, the rating of the three blade cap is only 15 amps. Either way the extension cord should only be loaded up to 80% of the wire rating. 20 x .8 = 16, 15 x .8 = 12.


How many watts will a 14 gauge extension cord handle?

A 14-gauge extension cord can typically handle up to 15 amps or 1800 watts for short periods, with a recommended continuous load of around 1440 watts to avoid overheating. It's always best to refer to the manufacturer's specifications for the specific extension cord in question.


Can you run 3 appliances 10-15 amps each through an extension cord with multiplug that is rated for 20 amps?

Not simultaneously because the total current must not exceed 20 amps.


Is it acceptable by OSHA to plug an extension cord into another extension cord-?

You can plug an extension cord into another extension cord. A extension cord is to help make doing something easier.


What is correct extension cord amp load for a 5500 volt generator?

For a 5500-watt generator, you should use an extension cord rated for at least 20 amps to safely handle the electrical load. Make sure the extension cord is in good condition and of the appropriate gauge to prevent overheating and ensure safe operation.


Extension Cord?

form_title= Extension Cord form_header= Install extension cords in your office. What size extension cord do you need?*= _ [50] What color extension cord do you need?*= _ [50] Do you need a 3 prong extension cord?*= () Yes () No


How do you make a 30 amp to 15 amp extension cord?

It is not recommended to make a 30 amp to 15 amp extension cord as it can be dangerous and violate electrical codes. Using the wrong amperage extension cord can lead to overheating, fires, or damage to electrical equipment. It is advisable to purchase the appropriate extension cord for the intended purpose.


2 500 watt lights 100ft extension cord calculate amps?

To calculate the amperage, use the formula: Amps = Watts / Volts. Assuming standard US voltage of 120V, the total power consumption of the lights is 1000 watts. Thus, Amps = 1000 watts / 120 volts = 8.33 amps. Be cautious not to exceed the extension cord's amperage rating to prevent overheating and potential fire hazards.


Can you connect a 6 outlet power bar to an extension cord?

There are several variables:First and most important, what will be the current draw? If the total number of amps exceeds the rating of either the power strip or the extension cord you're creating a fire hazard.Second, the wire gauge and length of the extension are important. You will loose voltage over distance and that is a function of the current draw, wire type and wire gauge. If you're trying to run 20 amps, don't use any less than a 12 gauge extension cord up to a maximum of 100 Ft. 15 amps, minimum 14 gauge.


Can a 15 amp extension cord be plugged into a 20 amp breaker?

It is not recommended to plug a 15 amp extension cord into a 20 amp breaker because the extension cord may overheat and pose a fire hazard. It is safer to use a cord that matches the amp rating of the breaker to prevent potential electrical issues.