Q: Can I run a double 30 amp breaker with 10-3 wire to receptacle for 240v MIG welder. Distance from main box to destination is 60 feet.?
Write your answer...
Submit
Still have questions?
magnify glass
imp
Related questions

How do you change a double pole 240v breaker to a single pole 120v breaker to allow a regular 120v receptacle to work?

See Discussion Page


Can you split a double pole 15 amp breaker into 2 single 15 amp breakers?

Yes. An everyday occurrence of this circuitry is in your kitchen counter split receptacles. The top half of the receptacle is a 15 amp circuit and from the same breaker the bottom half of the receptacle is another 15 amp circuit. A two pole single handle breaker is a common trip. If one of the circuits fed from the breaker faults the other connected circuit will shut off also. If you are talking about slot position in a breaker panel, you can remove the two pole breaker and install two single pole breakers.


Can you change a double pole 15 amp breaker into 2 15 amp breakers?

Yes. An everyday occurrence of this circuitry is in your kitchen counter split receptacles. The top half of the receptacle is a 15 amp circuit and from the same breaker the bottom half of the receptacle is another 15 amp circuit. A two pole single handle breaker is a common trip. If one of the circuits fed from the breaker faults the other connected circuit will shut off also. If you are talking about slot position in a breaker panel, you can remove the two pole breaker and install two single pole breakers.


What size breaker do you need for a stove?

From a 40 amp breaker, standard ranges have a three conductor #8 copper wire installed, terminating in a three pole four wire grounding receptacle. NEMA number 14-50R. Usually a 50 amp double throw breaker will do with 6 gauge wire


What size breaker is needed for 4 wire stove power cord?

Double 40 A two pole 40 amp breaker will feed a 3C/#8 cable, termination in a 4 11/16 square box. Receptacle NEMA number 14-50R.


Can you replace a 50A receptacle with a 30A 3-prong receptacle and keep the existing dedicated 20A pair of breakers?

No. The receptacle, wiring, and breaker ratings should all be matched properly. Replacing the 50A receptacle with a 30A receptacle isn't a problem, since the wire should be rated at least 50A. But a 30A receptacle should be protected with a 30A double pole breaker. The breaker only costs about $8.00, so why wouldn't you change it given you don't have to change the wire which would actually be expensive or time consuming? The fact that you mention a 50A receptacle protected by a 20A existing breaker isn't normal either. I would check to make sure the wiring is actually rated for 50A and that someone didn't just throw a 50A receptacle onto a 20A circuit. (This means your wiring should be at least #8AWG THHN Copper wire.) If you protected a 30A receptacle with a 20A breaker, the load might trip the breaker often, considering the appliance requiring a 30A receptacle probably requires about 30A. If you do not understand the work well enough to accomplish it yourself properly and safely, don't try it. Consult a professional electrician, as they are proficient enough to do it properly and safely. When working on electrical circuits and equipment, make sure to de-energize the circuit you will be working on. Then test the circuit with a definitive means to make sure it is off (multimeter with metal tipped leads, voltage tester with metal tipped leads, etc., not a non-contact tester, which is non-definitive.)


Can you change a double 15amp breaker into a double 20 amp breaker?

Absolutely not. If the existing breaker is a 15 amp breaker then the wiring that breaker is protecting is AWG # 14 gauge wire. A 20 amp breaker is used to protect AWG # 12 wire. Installing a double 20 amp breaker is just asking for a fire.


Does a double pole breaker double the amperage?

No. In North America a double pole breaker is used to obtain a voltage of 240 volts from the distribution panel. What ever the amperage rating stamped on the handle of the breaker is, that is the amperage that the breaker will trip at.


Is a double throw 15amp breaker the same as a 30 amp breaker amp?

You have a double pole breaker for 240Volt supply. The maximum current is 15 amp.


What's a double breaker 20 amps and 30 amps?

A double breaker is a breaker that has 2 switches on it. One of the switches is 20 amps and the other is 30 amps.


How do you change a 15 amp outlet to a 20 amp outlet?

The only way you can change a 15 amp to a 20 is you have to replace the 14 gauge wire going to it with a 12 gauge wire, then replace the 15 amp breaker with a 20 amp breaker. You can put a 15 amp outlet on a 20 amp circuit as long as there is more then one receptacle. A double receptacle counts as two receptacles. Steve Green Coeur d'Alene, Idaho


How do you rewire a 110 volt receptacle to produce 220 volts?

You would need to rewire it at the breaker box, and switch it from a single pole breaker to a double pole breaker. But when you do, all outlets and lights on that circuit will carry 240 volts. Best thing to do is run a new wire to the outlet you want to carry 240 volts. Put it on it's own circuit with the proper size breaker. I advise you to call an electrician unless you know what you are doing.