Q: Can I run a double 30 amp breaker with 10-3 wire to receptacle for 240v MIG welder. Distance from main box to destination is 60 feet.?
Write your answer...
Submit
Still have questions?
magnify glass
imp
Related questions

Can you use two 15 amp single pole breakers in place of a double pole 30 amp breaker?

No, you cannot use two separate 15 amp single pole breakers in place of a double pole 30 amp breaker. A double pole breaker is designed to simultaneously disconnect both circuit conductors, whereas using two single pole breakers would not provide the necessary protection for the circuit. It is important to use the correct size and type of breaker as specified by the electrical code for safety and functionality.


Is a double throw 15amp breaker the same as a 30 amp breaker amp?

You have a double pole breaker for 240Volt supply. The maximum current is 15 amp.


What's a double breaker 20 amps and 30 amps?

A double breaker is a breaker that has 2 switches on it. One of the switches is 20 amps and the other is 30 amps.


Does a double 50 amp breaker make a 100 amp?

No, a double pole 50 amp breaker protects a 240 volt supply at 50 amps. The number that is on the handle of the breaker is the amperage that the breaker will trip at if an overload occurs on the circuit.


How do you rewire a 220 volt receptacle to produce 110 volts?

To convert a 220-volt outlet to a 110-volt outlet, you would need to reconfigure the wiring at the circuit breaker panel by connecting the outlet to a different circuit. It's important to consult a qualified electrician to ensure the proper voltage conversion is done safely and in compliance with local electrical codes to avoid any hazards or damage to electrical components.


Should you buy double pole breaker or single pole?

It depends on the specific requirements of your electrical system. Single pole breakers are typically used for 120-volt circuits, while double pole breakers are used for 240-volt circuits. If you are unsure, it is recommended to consult with a qualified electrician to determine the appropriate type of breaker for your needs.


What size breaker should be used for a double oven?

50 amp breaker wired with AWG # 6 wire.


Can a 220 VAC breaker be single pole or does it have to always be a double pole breaker?

A 220 VAC breaker can be single pole or double pole depending on the application. For standard 220 VAC circuits like most household appliances, a double pole breaker is typically used. However, in certain situations where only one hot wire is needed, a single pole breaker can be used for 220 VAC circuits.


Where is the double-pole circuit breaker located?

before the load


Is it a fire hazard to double land wires on a breaker?

Yes!


Can a double pole circuit breaker be used for 2 different circuits I have a 20 amp double pole breaker want 2 circuits running 14 gauge wire?

can a 20 amp double pole circuit breaker be used for 2 different 120 v circuits using 14 - 2 wire


How many 30amp slots in a breaker box are needed for 240v cook top?

You would need one 30 amp double-pole breaker in the breaker box for a 240V cooktop.