Q: Can a 5 ton coil and furnace work with a 3 ton compresser?
Write your answer...
Submit
Still have questions?
magnify glass
imp
Related questions

Will a 4 ton condenser unit work with a 3 ton furnace?

not very well. a 4 ton system needs about 1600 cfm to provide it's full capacity of cooling. a 3 ton furnace puts out about 1200 cfm. in addition, the evap coil typically attached to the furnace needs to match the tonnage of the outdoor unit. so, the evap coil must be 4 tons. If you currently have a 3 ton furnace and evap coil, the system will not work, and you will most likely ruin the compressor in the outdoor unit.


Have a 5 ton condenser with a 5 ton coil have a 3 ton drive furnace any way this will work or will you have to get a 5 ton drive furnace?

You may be able to turn up the blower speed but you will probably still not get the appropriate cfm. You may be able to swap out the blower but you may run into problems with fitting the new one in place or the proper sizing of the return and supply duct work.


Can a 3 ton coil work with a 2 ton condenser?

Yes it will. Typically a coil is sized a 1/2 ton larger than the a/c out side for efficiency, but a whole ton bigger should still work


Can 3 ton a coil work with a 2 ton condenser?

Yes it will. Typically a coil is sized a 1/2 ton larger than the a/c out side for efficiency, but a whole ton bigger should still work


What size furnace would go with a 2.5 ton air conditioner?

Usually a 3 ton - 70,000btu furnace.


Do you have to have a 4 ton coil for a 4 ton ac unit?

The rating is technically a minimum. You could use a larger coil and have it work. But if its a Evaporator coil it will need to be matched on the far end with a similar or larger condenser coil. If the Condenser coil is larger it will probably just take a little more refrigerant.


5 ton condenser with a 3 ton drive furnace is there any way to fix this without replacing the furnace with a 5 ton drive?

No easy answer with the information given. You might be able to increase the blower speed but that probable wont get you enough air anyways. You might be able change the blower depending on your furnace. Depending on the evaporator coil 3 or 5 ton you either wont remove the proper amount of moisture from the air(the biggest part of what makes you feel cool) or there will not be enough air blowing over the coil and it will freeze up. Technically could put a freeze switch to turn of the condenser. Most likely you will wear out the condenser quicker then it should.


Can you replace a 2 ton coil with a 3 ton coil?

Maybe. The coil is not matched to a 2 or 3 ton truck It is matched to the engine and igniton control system. So it may be the same part #.


What happens if you install a 2 ton coil to a 3 ton air conditioning unit?

I'm not an air conditioning expert, but I would expect that the compressor will run a lot more than it needs to. A 2 ton coil will not cool as much air as a larger capacity 3 ton coil. Experts?


What are average prices for ac coil cleaning for 2 ton trane unit?

Between $490-765. That's a range for a 2 ton to 5 ton residential a/c coil cleaning.


A 3ton air conditioner has what size gas heater?

It could have any size heating furnace, the two are unrelated except for the size blower used in the furnace to support the 3 ton cooling system. But the fact remains you can get a 3 ton blower in 50,000 btu furnace, a 100,00 btu furnace and anything in between.