Q: Can the electrical sub panel be over stairs?
Write your answer...
Submit
Still have questions?
magnify glass
imp
Related questions

Why would the volts increase from the main panel to the sub panel?

Check the battery voltage on your tester. The voltage on the panel is the same throughout the whole electrical system.


Can you have a sub panel in a clothes closet?

No, nor under a stairwell. The electrical code stipulates that there has to be 3 feet or 1 metre in front of an electrical panel for clearance for easy access. The panel being in the closet does not fit this criteria.


How do you wire a circuit panel?

This type of question usually means you aren't ready to do this yourself. Study some electrical material and the National Electrical Code and work this answer out for yourself. If I were to give you an answer, you might attempt to do something you shouldn't be doing, and that may cost someone a shock, a home fire, or their life.


What is an electrical bonding strap?

How do i install aluminum bonding strap in sub panel of 100 amp service


When would you want to upgrade the main electrical panel vs just adding a sub-panel?

Depending on how many breakers you have in your exisiting panel if you only have a old 6 or 8 circuit panel then I would suggest a new panel, In the newer building world where you have a 20 or 30 circuit panel then I would suggest a sub panel.


How do you connect 200amp from main panel to sub panel to the lug of the min panel to lug of sub panel?

Not exactly sure what your question is and you need to make sure you are in compliance with electrical code for your jurisdiction. But, generally speaking you install a large breaker (let's say 100A 2 pole breaker to power the sub panel) just as you would install any other breaker in the presently used (hot) panel, and the proper sized cable then goes from old to new and terminates on the main lugs of the new panel. Ground and neutral are usually isolated from each other in the sub panel but depends on other factors as to location of the sub panel, etc.


What is a sub panel?

A sub-panel is always fed from a main panel. The main panel is situated where the electrical service wiring first enters the main structure on a dwelling plot or building site.A sub-panel can be situated within the same building as the main panel or it can be in a subsidiary building or structure (such as a garage, garden shed or workshop) that is separate from the main building.More informationA sub-panel is another name for a secondary breaker box, just as "the main panel" is another name for "the main breaker-box"."Breaker-box" and/or "panel" are just alternative short names that are used instead of the full name "circuit breaker box".


How do you wire from house to a summer house?

The summer house will be connected to the house system as a sub panel. Check the code rules on sub panels to make the installation conform to the electrical code.


How do you change out small sub panel to a bigger sub panel?

Home owner big jobIn the trade this is called a sub panel change out. It is a complicated job in as much as you have to know wire sizes, ampacity of wires and proper electrical workmanship. Such a project should be left to a licensed electrical contractor to take out the proper permits and call for proper inspections. By taking this route it will leave you confident that if any mishaps happen to the installation down the road your insurance company will be behind you 100%.


How many grounding rods are needed for 200 amp service?

It depends on where the sub panel is situated. If the panel is under the same roof as the main distribution panel then no ground rods are needed on the sub panel. If the sub panel is in a different building then a ground rod might be needed. There has been an electrical code rule change on this subject. Check with your local electrical inspector before installation so that it is done correctly.


Does a sub panel need a main breaker?

Answer for Canada, USA and countries running a 60 Hz, 120/240 volt, split supply service.The main distribution panelboard has to have a main disconnect. This has been in the electrical regulations since the late 50's.If the sub panel is in the same home under the same roof line, the sub panel enclosure does not need a main disconnect because it is just another branch circuit. Connecting a sub panel to a separate free standing garage or workshop is a different scenario and is governed by a different set of electrical code regulations.What needs to be done to the panelboard is physically remove the neutral bonding screw. This is the screw that bonds the panelboard enclosure to the neutral bus. By doing this it stops a secondary ground pathway for a fault current from the sub panelboard to flow back to the main panelboard on the sub panel's neutral feeder.The electrical code requires that there is only one position on an electrical distribution service where the distribution enclosure and the neutral bus join each other. That is at the main disconnect of the first over current device, which is the main service disconnect breaker or a fused disconnect switch whichever your system uses..


Can you feed a 60 amp sub panel from another 60 amp sub panel?

Yes