Best Answer

Yes, but they obviously cannot be simultaneously loaded their maximum loads because the 400-amp breaker will blow well before that.

Similarly, you can have multiple 100-amp panels fed from a 200-Amp main breaker, knowing that you will NEVER have 100 amps running in all panels at the same time.

User Avatar

Wiki User

11y ago
This answer is:
User Avatar

Add your answer:

Earn +20 pts
Q: Can two 225 amp panels be fed from a 400 amp breaker?
Write your answer...
Submit
Still have questions?
magnify glass
imp
Related questions

Duplex receptacle circuit given 15 amp breaker 225 amp load?

A 225 amp load will physically not be able to tie into a 15 amp breaker and a duplex receptacle as you can not get a 3/0 wire under the breaker and receptacle terminal screws.


Why does your 200 amp electric panel only have 20 breaker slots?

Some 200 amp breaker panels are made with only 20 slots.


How many circuits allowed in a 150 amp panel?

Panels are different. You can get 150 amp panels with 20 to 30 breaker spaces. The limit is stated by the manufacturer on a label attached to the panel. Hopefully you an find the label, sometimes it is on the inside of the cover


Can you tap off of a 200 amp service for 2 100 amp panels?

Yes, but at every reduction in wire size there has to be a breaker sized to the smaller wire size. The wire size for 100 amp panels is recommended at #3 copper conductor. From the 200 amp feeder panel you will require a 100 amp two pole breaker for each of the two 100 amp services. Keep in mind that if you run the 100 amp services close to maximum this will take away the capacity of the 200 amp service for other branch circuits coming off of it. Also keep in mind that if the panels are located, not in the same building as the 200 amp service that the 100 amp panels will be treated as separate services and will have to be constructed like a 100 amp service. This includes ground rods. Also the bonding screw will have to be removed that connects the neutral buss to the panel enclosure.


Is 60 amp breaker good for 225 stick welder?

The 225 amps is the secondary output amperage. Look on the machines nameplate to find the input amperage. It is that amperage that is needed to size the feed wire and there the breaker size. When you find that amperage you may want to re question the breaker size.


What is type of breaker for 41 amp's?

50 amp breaker.


How many breaker amps will a 200 amp service with no main breaker support?

Check the nameplate on the service panel. There it will tell you what the buss capacity is. On a 200 amp service nothing in the wiring configuration is allowed to be less than that the service rating. In the market there are 200 amp 42 circuit distribution panels.


How do you turn a 30 amp circuit into a 15 amp cicuit?

Replace the 30 Amp Breaker with a 15 Amp breaker.


How can you install two - two amp breaker boxes from one meter can?

The smallest size in breaker panels is 30 amps and the smallest breakers that can be installed into a 30 amp panel are15 amps. If more info is needed go to the discussion page tab and explain what you are trying to do.


Can you use a 60 amp breaker with a 50 amp overcurrent device?

A 50 amp breaker is an overcurent device.


Is a double throw 15amp breaker the same as a 30 amp breaker amp?

You have a double pole breaker for 240Volt supply. The maximum current is 15 amp.


Can a 4 amp breaker be used to replace a 35 amp breaker for ac unit?

NO!