answersLogoWhite

0


Want this question answered?

Be notified when an answer is posted

Add your answer:

Earn +20 pts
Q: Can you get a contactor to fit into a switch plate?
Write your answer...
Submit
Still have questions?
magnify glass
imp
Continue Learning about Electrical Engineering

How do you wire contactor for two light circuits through a time clock?

How do you wire a time clock with a contactor with a override switch


How do electro pneumatic contactors work?

A contactor is an electrically controlled switch (relay) used for switching a power circuit. an electro pneumatic contactor is similar to the above except it uses a pneumatic signal to initiate the switching of the electric power circuit. an electro magnetic contactor is a contactor driven by an electric control signal. It us usually just called a contactor.


What is an electrical switch that opens and closes under the control of another electrical circuit?

If it is a physical switch, this is called a "relay" or a "contactor". If it is a semiconductor device, it is typically a triac, SCR or a thyristor.


How do you wire a DOL starter controlled by a pressure switch for a water pump?

Answer for USA, Canada and countries running a 60 Hz supply service.The wiring of this type of installation is quite elementary. It is all about the control voltage for the magnetic contactor and having the pressure switch in series with the contactor's coil.If the pump supply voltage is 120 volts, take a wire from L1 on the contactor and place it on the normally closed contact point on the overload block.From the N.C. contact on the overload block take a wire to one side of the pressure switch.From the output side of the pressure switch contact take the wire back to one side of the contactor's coil.Connect the other side of the contactor's coil to the neutral wire from the supply.Now you will have three components in series with each other. The overload block, the pressure switch and the contactor's coil as the load of the circuit. When the pressure switch closes due to low pressure the coil will be energized.If the pump motor goes into an overload condition, the overload block contacts will open and de-energize the contactor's coil and the pump will shut off.As always, if you are in doubt about what to do, the best advice anyone should give you is to call a licensed electrician to advise what work is needed.Before you do any work yourself,on electrical circuits, equipment or appliances,always use a test meter to ensure the circuit is, in fact, de-energized.IF YOU ARE NOT ALREADY SURE YOU CAN DO THIS JOBSAFELY AND COMPETENTLYREFER THIS WORK TO QUALIFIED PROFESSIONALS.


Definition of coil in contactor?

The coil in a "Contactor" is essentially an electromagnetic coil that provides the driving force to close the contacts in a Contactor. When the "Coil" is energized by a lower control voltage usually from some type of controller such as a PLC, the Normally-Open contactor will close or in the oposite case, the Normally-Closed contactor will open.

Related questions

How do you wire contactor for two light circuits through a time clock?

How do you wire a time clock with a contactor with a override switch


How many wires to control a mechanically held contactor?

A contactor is a type of switch. However this switch uses electricity to power an electromagnetic coil to switch on or off power. Hence a contactor needs 2 wires - A live/hot wire and a neutral wire. Generally these are connected across the A1 and A2 terminals of the contactor.


What usually cause the star contactor to burn on a star delta starter?

A lot of designers will fit an under rated star contactor, partly for cost saving purposes and partly down to the fact that the star contactor will only stay energised for a brief period. Burning out the star contactor could be down to it staying in circuit too long, not changing over to delta, a timer malfunction holding in the star contactor or switch that is defective in the control circuit. Another cause could be your motor is drawing excess current.


How do you wire up a 208v single phase motor with micro switch?

if you are using the pressure switch to control a 3phase pump chances are it already has a magnetic starter and a single pole control circuit i have seen small 3phase air compressors with the contacts driven right off the diaphragm bigger ones usually have 110 volt controls i would be concerned about the current rating of the switch if you are trying to switch the motor directly there are many single phase compressors that run directly from the pressure switch


What is a contactor coil?

a contactor is generally looks like a small box connected to an electric circuit. it is what controls electricity flow to a motor. in the middle is normally a way to push in the contactor to manually check to see if either the motor works or if you have electricity.


In the field of electronics what is the meaning of the word contacter?

A contactor is an electrically controlled switch. It is used for switching a power circuit. A contactor is controlled by a circuit which has a much lower power level than the switched circuit.


How do electro pneumatic contactors work?

A contactor is an electrically controlled switch (relay) used for switching a power circuit. an electro pneumatic contactor is similar to the above except it uses a pneumatic signal to initiate the switching of the electric power circuit. an electro magnetic contactor is a contactor driven by an electric control signal. It us usually just called a contactor.


What does a 4 pole contactor do?

It makes and breaks four separate contacts. Think of a switch for example that connects one wire to one wire. A 4 pole contactor is like 4 separate switches going on together.


Can 125v magnetic switch be used in 12v system?

If what you term as a "magnetic switch" is an electrical contactor, then the answer is yes.A couple things to keep in mind. I presume the 125 volts mentioned is the coil voltage of the contactor.The switched voltages and amperage or horsepower allowed by the contactor is on the contactor's nameplate. This is the maximum voltage that can be applied to the contactor which includes 12 volts.The amperage of the 12 volt device is not mentioned and this should not exceed the maximum allowed current of the lowest voltage rating of the contactor. This is especially true if the 12 volts is Direct Current. An example of this could be a starter on a car. When the starter starts to crank it could be in the neighbourhood of 300 amps DC. As you can see this would fry the contacts of a normal AC rated contactor.


What relay would you use to switch 400 watts of fluorescent lights?

There are special contactor that are made to switch lighting loads. These relays and not wattage rated but amperage rated. Use the following formula with the voltage that you are going to use to find the size of contactor that you need. I = W/E, Amps = Watts/Volts.


What is an electrical switch that opens and closes under the control of another electrical circuit?

If it is a physical switch, this is called a "relay" or a "contactor". If it is a semiconductor device, it is typically a triac, SCR or a thyristor.


How to choose rating of contactor in star delta starter?

As well as motors, contactors also have kW and Ampere ratings. Have a look on the name plate of your motor and you will see its maximum current draw (amps). Select a contactor with a current rating greater than this.