Yes.
But the NEC requires that your first disconnect be installed as close as practical to where the service enters the building. So if the bedroom isn't where the service enters the home, you will have to install a stand-alone disconnect where it does and then wire to your panel.
Yes a breaker panel can be located in a hall. In fact a lot of apartments have them in that location just as you come in the main door to the apartment.
The panel and breaker have to be of the same manufacturer. This way the breaker will fit into the panel. If the panel has a push in bus bar, the breaker must also be the type to accept the bus bar. If the bus bars in the panel are of the bolt in type then the breaker also has to be a bolt in breaker.
No, a Cutler Hammer will not work in a GE panel or vice versa.
You can. Using these size breakers in a 60 amp sub panel might be pushing the limit for breaking the sub panels feeder breaker. The breaker feeding the sub panel will have to be no bigger than 60 amps because of the main bus bar capacity of the sub panel. It would be better to install a 100 amp sub panel and then there would be a bit of a buffer and you will have the ability to add additional small load circuits.
A 100-A sub-panel would be fed from a 100-A breaker.
yes
Yes a breaker panel can be located in a hall. In fact a lot of apartments have them in that location just as you come in the main door to the apartment.
The panel and breaker have to be of the same manufacturer. This way the breaker will fit into the panel. If the panel has a push in bus bar, the breaker must also be the type to accept the bus bar. If the bus bars in the panel are of the bolt in type then the breaker also has to be a bolt in breaker.
To prevent frost behind a breaker panel, ensure proper insulation is installed around the breaker panel to maintain consistent temperature levels. Additionally, seal any gaps or openings around the panel to prevent cold air from entering and causing condensation. Regularly check for any signs of moisture buildup and address any issues promptly.
To perform a Pushmatic breaker replacement in your electrical panel, follow these steps: Turn off the main power supply to the panel. Remove the cover of the electrical panel. Identify the Pushmatic breaker that needs to be replaced. Carefully disconnect the wires connected to the breaker. Remove the old breaker by gently pulling it out. Insert the new Pushmatic breaker into the slot. Reconnect the wires to the new breaker. Put the panel cover back on. Turn the main power supply back on and test the new breaker. Remember to always prioritize safety and consult a professional if you are unsure about any step.
I wnt to install a tandem breaker but my panel box won't let me. Why?
To properly add a breaker to a panel, first turn off the main power switch. Remove the panel cover and identify a free slot for the new breaker. Connect the breaker to the panel's bus bar and then connect the circuit wire to the breaker. Secure the breaker in place and replace the panel cover. Finally, turn the main power switch back on.
To add a breaker to a panel, follow these steps: Turn off the main power supply to the panel. Remove the panel cover. Identify a free slot in the panel for the new breaker. Insert the new breaker into the slot and secure it in place. Connect the wires to the new breaker according to the manufacturer's instructions. Replace the panel cover and turn the power back on.
To install a 50 amp breaker in an electrical panel, first turn off the power to the panel. Remove the panel cover and locate an open slot for the breaker. Insert the breaker into the slot and connect the wires to the breaker terminals. Make sure the wires are securely attached and tighten the screws. Finally, replace the panel cover and turn the power back on to test the breaker.
It is inserting a breaker into a service panel.
15 amp breaker.
You can't wire 2 beedrooms on one breaker.