Best Answer

A 30 amp breaker is designed to trip at an earlier point than a larger 40 amp breaker so one appliance that operates on lower amperage level could be unsafe or damaged before it could trip the higher 40 amp breaker. Also, the existing wiring may not be rated for 40 amp service.

User Avatar

Wiki User

13y ago
This answer is:
User Avatar

Add your answer:

Earn +20 pts
Q: Can you replace your current cooker fuse 30 amp with a 40 amp circuit breaker?
Write your answer...
Submit
Still have questions?
magnify glass
imp
Related questions

When the power cuts off after switching on an appliance what do I do?

You probably popped the breaker. The appliance is drawing too much current for that circuit (or is combined with too many other appliances on that circuit). Unplug it, turn the breaker back on. Try to find a different circuit to operate it on, or move other appliances to other circuits to reduce the load. If you own your residence you might be able to hire an electrician to completely rewire that circuit with larger capacity wire and breaker and changing the outlets also. This will get expensive though. I cannot use my microwave cooker and my stand mixer at the same time, together they will trip the breaker for the kitchen outlets, but one at a time is OK. It might also be an earth fault in the appliance - As stated turn off other appliances on the same circuit (that should cancel out any over load) and test again . If the breaker drops then the appliance is the issue


Can you add sockets to a cooker circuit?

no


Can you add sockets onto cooker circuit?

possibly


What is the difference between a halogen cooker and a convection cooker?

A halogen cooker is the same thing as an electric stove and a convection cooker uses a circulating current of hot air to cook foods.


What fuses should be used for an electric range?

More information about the make and model of the range, cooker, oven, etc. is needed to be able to answer this question, assuming it is asking about the fuses to go inside the frame of the appliance itself.But if it is asking a general question about the size of circuit breaker that should be used to protect a range circuit, see the answer to the Related Question shown below.


How do you wire a cooker outlet?

You would have to install:a socket outlet with prongs of the correct size - which must include a ground prong;fed by wiring of the correct size;protected by a circuit breaker of the correct type and size;all to match the maximum current that will be drawn by the cooker you plan to use at that location.As always, if you are in doubt about what to do, the best advice anyone should give you is to call a licensed electrician to advise what work is needed.Before you do any work yourself,on electrical circuits, equipment or appliances,always use a test meter to ensure the circuit is, in fact, de-energized.IF YOU ARE NOT ALREADY SURE YOU CAN DO THIS JOBSAFELY AND COMPETENTLYREFER THIS WORK TO QUALIFIED PROFESSIONALS.


What size cable for your 9700 watt cooker?

To answer this question the voltage of the cooker is needed.


What is electrical domestic circuit?

Answer for UK, Europe and countries running a 50 Hz supply service.It is a set of power cables carrying electric power round domestic premises.In the UK you might have a lighting circuit for the lights, a ring circuit for power sockets and a cooker circuit to supply the cooker. Typical ratings are 10 A for lights and 30 A for power and cooker circuits. Extra curcuits might be added for space-heating and a shower.Each of these circuits is separately fused to that if there is a fault leading to a blown fuse, not all the power disappears.


Why does the air conditioner keep tripping the electricity?

Have you tried changing you breaker? Sometimes when breakers get weak they will still function most of the time, but when the a/c kicks on it will trip. Is it the indoor portion of your AC or the outside? The circuit is probably overloaded. 110V air conditioners draw quite a bit of current. If you have many other devices on the same circuit that is why the breaker is tripping. To solve this you need to run another circuit. Consult an electrician if you don't know how ot do this.


What can you use to replace the jiggly thing on your pressure cooker?

crumpled-up aluminum foil


What are the typical loads of electricity found rural domestic in United kingdom?

Lighting circuit - 5 amps Ring main - 13 amps Cooker circuit - 30 amps


What is a green wire with a yellow stripe used for?

The wire with green/yellow insulation is the circuit protective conductor "cpc" generally know as the earth. This wire provides a return path for electricity under fault conditions to ensure that the circuit protective device (fuse or circuit breaker) operates quickly enough to disconnect the circuit from the supply. It should be present and properly connected in all standard UK domestic and commercial circuits. Were a fault to develop in an appliance with with metal casing such as an electric cooker, without the cpc the metal casing would be live and remain so until a person or animal came into contact with it. At this point the fault current would flow through them usually with lethal consequences.