The white wire would go to the neutral bar. Just be sure of the shunt trip voltage required for the breaker and land the white wire on the appropriate neutral bar in the correct panel.
In electrical engineering, shunt means 'parallel'.
connect the arteriole to the venules
A shunt generator is used to provide electrons (electrical energy) to the electroplating machine.
what is meant by shunt motor
You would need to take the "input" wire for the shunt trip breaker to an electrical switch (not alarm initiating switch, which are DC voltage rated) within the Automan unit and connect to the "Common" connection and the "return", the wire to the actual shunt circuit of the breaker, from the "Normally Open" connection of the switch. When the unit activates, the switch will be placed into "Closed" position, therefore completing the circuit and activating the shunt coil.
In electrical engineering, shunt means 'parallel'.
connect the arteriole to the venules
Shunt means parallel only..................
A shunt generator is used to provide electrons (electrical energy) to the electroplating machine.
Shunt resistors are used with ammeters; voltmeters require series resistors.
Connect to the circuit neutral wire which should also be white.
what is meant by shunt motor
I can only assume that you are attempting to connect 480VAC coil from a elevator to a fire system in order to shunt the elevator. In order to do this you will need a shunt trip breaker rated for this use.
You would need to take the "input" wire for the shunt trip breaker to an electrical switch (not alarm initiating switch, which are DC voltage rated) within the Automan unit and connect to the "Common" connection and the "return", the wire to the actual shunt circuit of the breaker, from the "Normally Open" connection of the switch. When the unit activates, the switch will be placed into "Closed" position, therefore completing the circuit and activating the shunt coil.
A shunt is an electrical conductor joining points of a circuit, into or out of which current can be diverted. The water-cooled refers to the way it's kept cool, as insulation is not provided.
A blood vessel that provides a direct link between an artery and a vein is a shunt vessel.For example, shunt vessels connect arterioles and venules in the skin, to cut down heat loss in cold weather.In surgery, a shunt is a device used to connect two vessels or chambers of the cardiovascular system.
Yes, you can. If your shunt trip is 120 volts, just get 120 volt from your panel and take it to your ansul normally open contacts than to your shunt trip braker. than when your ansul system trips it will trip your shunt braker.