The input power, that is, the power required to operate the pump should be stated in Hp (horsepower) on the pump's nameplate. It can also be calculated by the 3-phase power equation:

P(in Hp) = VI(1.73) = Rated Voltage x Rated Current x 1.73/ %Efficiency

If this is a consumer grade pump that operates on 120Vac, then the equation becomes P = VI, simply multiply the operating voltage, 120 x current (which is the number followed by the letter "A".

The nameplate might look something like this:

___________________

| |

| Make: xxxxxx |

| Model: xxxxxx |

| Volt: xxx |

| Amp: xxx |

| %Eff: xx |

| |

|__________________|

The output power, which really isn't technically power, but rated in Gpm (gallons per minute), or capacity should also be on the nameplate. If you have the make, model, and (not necessarily needed) the serial number (also on the nameplate) you could call the manufacturer's customer service dept. As an application engineer, I have contacted countless manufacturer's service dept's for assistance. It is now big deal to them, they will be happy to answer your questions.

If it is the absorbed power of the pump to allow you to select a suitable motor then this is a function of the generated head, flowrate, specific gravity of the fluid and the pump efficency from the OEM / pump performance curve.

For those of us not in the US or using English units then the power can also be specified in kW.

In simple terms Power (kW) = Flow x Head x SG / (367 x Effy)

Where Flow is in cubic metres / hour, head is in metre, Specific Gravity (SG) being a dimensionless unit - cold clean water SG = 1 and efficency as a % from the curve or other means.

If you are trying to evalaute wire to water efficency then you can set efficency in the equation above to 1 and then ratio the input (measured power) to output power (calculated water horse power) to obtain the overall efficency.

User Avatar

Wiki User

9y ago
This answer is:
User Avatar
More answers
User Avatar

Wiki User

14y ago

Calculate or calibrate? Calculate - apart from reference to tables for the pump, impossible. Calibrate - get a stop-watch and a very big bucket, switch on and stand back. There should be a capacity on the plate on the pump, or a design or model number that you can use to get a capacity figure, either from a catalogue or the manufacturer.

This answer is:
User Avatar

User Avatar

Wiki User

9y ago

When calculating the discharge of a centrifugal pump, the pressure at any point in a liquid can be thought of as being caused by a vertical column of the liquid which, due to its weight, exerts a pressure equal to the pressure at the point in question. The formula for calculation is: multiply the pressure in psi times 2.31. Divide this total by the specific gravity.

This answer is:
User Avatar

User Avatar

Wiki User

10y ago

Conduct a test as follows:

1. Place the suction side or suction hose of the pump into a fluid.

2. Allow the pump to pump the fluid into a the first container until the pump is pumping a steady fluid flow.

3. Switch the output hose of the pump to an adjacent empty (second) container whiile simultaneously starting a counter (i.e. count up timer). You may need a friend to operate the timer if you aren't sufficiently coordinated to manage both actions.

4. Allow the pump to pump the fluid for whatever amount of time you desire (e.g. 40 seconds).

5. Measure the fluid volume in the second container.

If the volume of fluid from the second container is 3 gallons and it took 40 seconds to pump the 3 gallons, then do the following calculations:

3 gallons / 40 seconds = .075 gallons/second

Since most pumps are rated by the gallons per hour that they pump, do the following calculation:

.075 gallons/sec * 3600 sec/hr = 270 gallons/hr

Note: There are 3600 seconds in 1 hour (60 sec/min * 60 min/hr = 3600 sec/hr

This answer is:
User Avatar

User Avatar

Wiki User

11y ago

I want the formula related to centrifugal pumps power,capacity and voltage.

This answer is:
User Avatar

User Avatar

Wiki User

11y ago

2999sq/ft

This answer is:
User Avatar

Add your answer:

Earn +20 pts
Q: How do calculate the fire pump capacity?
Write your answer...
Submit
Still have questions?
magnify glass
imp
Related questions

Jockey pump capacity how related with main fire pump capacity?

5 hp


How do you calculate chilled water system volume if knowing chiller capacity?

just multiply pump capacity by 3


How you calculate the capacity of cement silo?

Dear Friend, calculate the volume of the silo ie., nothing but the capacity you required.


How do you calculate the capacity of a machine using formula?

how to calculate the embroidery machine capacity and Embroidery factory capacity and efficiency.


How do you calculate machine capacity?

how to calculate injection molding m/c capacity


What is a fire Pump churn test?

The fire pump churn test, is when an operator runs the fire pump without the flow of water


What instrument can be used to calculate specific heat capacity?

A calorimeter can be used to calculate specific heat capacity.


What type of pump is jockey pump?

A jockey pump is a small pump connected to a fire sprinkler system and is intended to maintain pressure in a fire protection piping system to an artificially high level so that the operation of a single fire sprinkler will cause a pressure drop which will be sensed by the fire pump automatic controller, causing the fire pump to start. The jockey pump is essentially a portion of the fire pump's control system.


How do you calculate the bsc zte bsc capacity in erlang?

I want to know how to calculate the Capacity (Erglang) of one BSC in GSM


How do you calculate cooling capacity?

boi


Calculate forced vital capacity?

i want to know how to calculate FVC....


How do you calculate press machine capacity?

machine capacity=looknath/rupesh *100