answersLogoWhite

0


Best Answer

The coil can be operated by taking one leg of the 240 volts from the top of the contactor and connecting it to one terminal of the coil. Take the other leg of the 240 volts from the top of the contactor and connect it to the device used to turn the contactor off and on. From this switching device take the switched wire and connect it to the other terminal on the contactor's coil. Now when the switching device is activated the contactor will open and close.

Before you do any work yourself,

on electrical circuits, equipment or appliances,

always use a test meter to ensure the circuit is, in fact, de-energized

IF YOU ARE NOT REALLY SURE YOU CAN DO THIS JOB

SAFELY AND COMPETENTLY

REFER THIS WORK TO QUALIFIED PROFESSIONALS.

User Avatar

Wiki User

13y ago
This answer is:
User Avatar

Add your answer:

Earn +20 pts
Q: How do you activate 240v coil using a 240v contactor?
Write your answer...
Submit
Still have questions?
magnify glass
imp
Continue Learning about Electrical Engineering

Definition of coil in contactor?

The coil in a "Contactor" is essentially an electromagnetic coil that provides the driving force to close the contacts in a Contactor. When the "Coil" is energized by a lower control voltage usually from some type of controller such as a PLC, the Normally-Open contactor will close or in the oposite case, the Normally-Closed contactor will open.


What causes an electrical contactor to make a buzzing noise when activated and what should be done about it?

Contactor chatter can be caused by a broken shading ring winding on the pole face of the contactor. Low voltage to the coil can be another reason for contactor chatter. A constant hum on a contactor will be caused by misalignment to the two pole faces. Check for rust building up on the two surfaces.


What would cause a lighting contactor to hum vigorously?

The first thing that springs to mind is that the pole faces of the contactor are dirty. If the contactor is in a position where it can get weathered, it would probably be a rust built up. Dis assemble the contactor and emery cloth the pole faces until they are shiny again. A light wiping of oil will increase the time between cleanings. If the sound is more like a chatter then the shading coil on the contactor's pole face could be cracked or broken. This small copper coil is used to induce magnetism into the pole face to hold the contactor closed as the voltage transits through the zero voltage of the sine wave cycle.


How do electro pneumatic contactors work?

A contactor is an electrically controlled switch (relay) used for switching a power circuit. an electro pneumatic contactor is similar to the above except it uses a pneumatic signal to initiate the switching of the electric power circuit. an electro magnetic contactor is a contactor driven by an electric control signal. It us usually just called a contactor.


How do you wire a compressor switch?

Take a wire from one of the line terminals L1 to one side of the contactor coil. Take another wire from the second line terminal L2 and put it to one side of a N.C. contact on the overload block. From the other side of the N.C. contact on the O/L block take a wire to the N.C. terminal on the pressure switch. From the other side of the N.C. contact on the pressure switch terminal connect the wire to the other side of the coil. This configuration will be using the same coil voltage on the contactor as that of the supply voltage.

Related questions

Can 240v coil contactor be connected to 110v supply?

no


Definition of coil in contactor?

The coil in a "Contactor" is essentially an electromagnetic coil that provides the driving force to close the contacts in a Contactor. When the "Coil" is energized by a lower control voltage usually from some type of controller such as a PLC, the Normally-Open contactor will close or in the oposite case, the Normally-Closed contactor will open.


How is a Blowout coil connected?

A blowout coil connected in series with contactor's auxiliary contacts that shunt around the main contactor contacts. The coil is out of the circuit when the main contactor contacts are closed and in the circuit when the main contactor contacts are open.


How do you test a good and working contactor?

A contactor is tested by using a device called a Multimeter. By setting the multimeter to ohms and rx1 you can clip both prongs to the coil. If the multinmeter moves the contactor is good. If it doesnt move its bad.


What is the difference between an definite purpose contactor and a lighting sontactor?

A definite purpose contactor is designed (and rated) for a specific load. So a lighting contactor is one example of a definite purpose contactor. A motor starter contactor is another example. So, a lighting contactor is a definite purpose contactor, but a definite purpose contactor is not necessarily a lighting contactor (it might be a motor starter, for instance).


How relay is used to control induction motor?

If you want to control induction motor using a control relay give neutral directly to the one point of coil of relay & one point of coil of contactor then give control supply through push button to second point of coil of relay. use one NO point of relay and give supply to coil of contactor. and also use one NO of contactor for holding the contactor & take OFF (NC) in the starting to stop motor after complition of work. It is jut like an Direct On-line starter.


You found a 220volt coil on a 3 phase motor contactor and the one side of the coil is feed from B phase and the other side is also feed from B phase it would not pull in the contactor?

your not completing the circuit your only using one phase for a three phase motor


What is the function of an electrical coil in a basic circuit?

There are a couple of examples that come to mind where there is a coil in a circuit. One is, the coil is used as a choke to block harmonics from going down the electrical line. Another example of a coil in the line is the coil in a magnetic contactor. When this coil is energized the contacts of the magnetic contactor close.


How many wires to control a mechanically held contactor?

A contactor is a type of switch. However this switch uses electricity to power an electromagnetic coil to switch on or off power. Hence a contactor needs 2 wires - A live/hot wire and a neutral wire. Generally these are connected across the A1 and A2 terminals of the contactor.


How does a shading coil in a contactor actually work?

A shading coil in a contactor is used to hold the AC contactor's pole faces closed during the transition of the voltage through the zero voltage phase of an electrical cycle.For an excellent description see related links below.


What is a contactor coil?

a contactor is generally looks like a small box connected to an electric circuit. it is what controls electricity flow to a motor. in the middle is normally a way to push in the contactor to manually check to see if either the motor works or if you have electricity.


What should the resistance on a 30 amps triple pole contactor measure?

If the coils pulling the contactor in, you should have negligible resistance. If the contactor is not in, then you should have open circuit. Unless your measuring the resistance of the coil, in which case it will roughly be around 30ish ohms im guessing, depends on the coil voltage