You don't, you need a three wire to correctly make the connection.
Black & Red are hot, and White is neutral. If it has no place to connect neutral connect neutral to ground.
Change the outlet to a grounded one. Get an adapter that goes from 3 prong to 2. Break the ground prong off. Any one of these will work.
Do not use this type of cable to feed a 120/240V dryer outlet. The outlet is ungrounded, and the third conductor is neutral not ground. Your ground wire must be sheathed by code. You cannot use the bare neutral conductor as ground. Diagram Did Not Come Through. You Have a 3 Prong Connector. The Prong On The Bottom By Its Self Connect The Bare Wire. That Is What Was # 3 Connect The Others To The Two Prongs Next To Each Other. Hope This Makes Some Sense (1) (2) (3) Connect White To (1), Connect Black To (2) Bare (3) Good Luck
YES - it will work fine, and hopefully you have grounding in the plug. If you do not, you should also get surge protection and a safety cap when not using. The 3 prong will not create a ground, so it will not change the fact that it is dangerous not to have ground (you know kids and outlets).
Yes, provided the outlet has a three element receptacle. The third prong is ground. If you use an adapter that connects three prongs to a two slot outlet there is a shock danger.
Black & Red are hot, and White is neutral. If it has no place to connect neutral connect neutral to ground.
Change the outlet to a grounded one. Get an adapter that goes from 3 prong to 2. Break the ground prong off. Any one of these will work.
Only if you wanted to fry your hair.for God sake(and yours)buy a new cord to hook up your dryer
Do not use this type of cable to feed a 120/240V dryer outlet. The outlet is ungrounded, and the third conductor is neutral not ground. Your ground wire must be sheathed by code. You cannot use the bare neutral conductor as ground. Diagram Did Not Come Through. You Have a 3 Prong Connector. The Prong On The Bottom By Its Self Connect The Bare Wire. That Is What Was # 3 Connect The Others To The Two Prongs Next To Each Other. Hope This Makes Some Sense (1) (2) (3) Connect White To (1), Connect Black To (2) Bare (3) Good Luck
Yes, provided that you have a ground wire in the box and that the ground wire is properly connected in the electric panel.
There is not enough information stated as to what you are trying to do.
Buy a tester. They are very cheap and will tell you at a glance if the outlets are wired correctly. The only other way is to remove the outlet and look see. But if it is a 2 prong outlet with no ground hole then it does not have a ground.
YES - it will work fine, and hopefully you have grounding in the plug. If you do not, you should also get surge protection and a safety cap when not using. The 3 prong will not create a ground, so it will not change the fact that it is dangerous not to have ground (you know kids and outlets).
Yes, provided the outlet has a three element receptacle. The third prong is ground. If you use an adapter that connects three prongs to a two slot outlet there is a shock danger.
The four blade dryer plug brings a separate ground wire from the machine to the electrical grounding system. The three blade dryer plug depended on the neutral wire of the plug to make this connection.
Disregard the neutral
It may be a 220 Dryer, and you will need a new outlet installed. There should be no extra wires when connecting the Power cord to the plug