To reset a GFCI you need to first correct any ground faults in the circuit - or some other other fault in the equipment and/or its flexible cord and/or its plug - being protected by the GFCI, which is causing an imbalance in the currents flowing in the hot and neutral wires. Ground faults are usually caused by wet electrical equipment. Then you need to press the RESET button on the GFCI.
The GFI outlet was there for a reason, such as a bathroom or other location around water where there is more risk of a shock being harmful or lethal. If it was a GFI, keep it a GFI. Also that outlet may be protecting other standard outlets being fed from the GFI. You can only after the house has passed inspection after the house was finished being built. It's a requirement that all new houses have to have a GFI wherever there's water, but it's perfectly legal once you buy the house to do this modification. However, it's highly not recommended unless there's more than one GFI outlet hooked up to the same circuit. If there's more than one, it's optional to take one off and replace it with a standard outlet because you really only need 1 GFI outlet to protect the rest of the outlets on the same circuit. But if it's already there, just leave it as is. Example: power box>GFI>normal>normal>GFI>normal; end; You can take off the second GFI and and every normal non-GFI outlet will function like GFI. If you take off the left one, only the last normal outlet will be GFI protected, the ons to the left wouldn't.
No
Yes, that is fine.
Yes, there are several ways to wire them. If you only want some plugs to be GFI (only the actual GFI plugs) protected then you wire them using just the "load" screws. if you want the whole circuit to be protected (or just two separate portions) the GFI plug must be first in the circuit and the protected plugs wired off of the "line" screws on the receptacle. Check the instructions, local codes, and with an electrician of course. Be safe, GFI circuits can be tricky.
GFI
Check the circuit panel / breaker box. The tripped breaker should be partway between 'OFF' and 'ON'. If nothing else, turn the breakers off then on, one at a time and when the tripped breaker is reset, the circuit should be live again. Also check GFI outlets. If one is in fault condition, it will need to be reset. If the tripped GFI outlet is protecting other outlets, they will come back when the tripped GFI is reset. These sockets seem to hide in many cases... Behind microwave ovens for example or refrigerators.
It depends. It could be improperly installed. Outlets can be GFI protected by using a GFI rated breaker in the main panel box. Look for a breaker in the panel box that has a push to test button on it. Press the push to test button then plug something into the outlet to see if it still works. If the breaker turns off the power then it is GFI protected. To reset it flip the breaker to the fully of position then back to the on position.
No. That is not the purpose of a GFI.
GFI Software was created in 1992.
GFI Group was created in 1987.
GFI Russia was created in 1996.
The population of GFI Group is 2,010.
The GFI outlet was there for a reason, such as a bathroom or other location around water where there is more risk of a shock being harmful or lethal. If it was a GFI, keep it a GFI. Also that outlet may be protecting other standard outlets being fed from the GFI. You can only after the house has passed inspection after the house was finished being built. It's a requirement that all new houses have to have a GFI wherever there's water, but it's perfectly legal once you buy the house to do this modification. However, it's highly not recommended unless there's more than one GFI outlet hooked up to the same circuit. If there's more than one, it's optional to take one off and replace it with a standard outlet because you really only need 1 GFI outlet to protect the rest of the outlets on the same circuit. But if it's already there, just leave it as is. Example: power box>GFI>normal>normal>GFI>normal; end; You can take off the second GFI and and every normal non-GFI outlet will function like GFI. If you take off the left one, only the last normal outlet will be GFI protected, the ons to the left wouldn't.
Are you sure it is the bulb that its blowing and not the Gfi tripping? Try resetting the gfi. Also try swithing to an incandescent bulb and test your gfi. Also test the cfl in a non-gfi outlet. Cfls return power they don't use and may make the gfi trip. I am not an electrician, just personal experience.
Don't ! get another GFI plug. there 4 dollars and the instructions come with it
GFI surpasses Nessus when targeting Windows hosts
The symbol for GFI Group Inc. in the NYSE is: GFIG.