Q: Can you put two switches and GFI receptacle in same box?
Write your answer...
Submit
Still have questions?
magnify glass
imp
Continue Learning about Electrical Engineering

How do you replace a GFCI outlet?

The GFI outlet was there for a reason, such as a bathroom or other location around water where there is more risk of a shock being harmful or lethal. If it was a GFI, keep it a GFI. Also that outlet may be protecting other standard outlets being fed from the GFI. You can only after the house has passed inspection after the house was finished being built. It's a requirement that all new houses have to have a GFI wherever there's water, but it's perfectly legal once you buy the house to do this modification. However, it's highly not recommended unless there's more than one GFI outlet hooked up to the same circuit. If there's more than one, it's optional to take one off and replace it with a standard outlet because you really only need 1 GFI outlet to protect the rest of the outlets on the same circuit. But if it's already there, just leave it as is. Example: power box>GFI>normal>normal>GFI>normal; end; You can take off the second GFI and and every normal non-GFI outlet will function like GFI. If you take off the left one, only the last normal outlet will be GFI protected, the ons to the left wouldn't.


Can you put a receptacle on the end of an extension cord?

Yes, the receptacle will have to be terminated in a receptacle box of some kind. Construction usually use an FS type box with a 1/2" hub. A 1/2" strain relief connector is used to hold the extension cord into the FS box. Wire the white wire of the cord to the silver screw, black coloured wire to the brass screw and the green wire to the green ground screw on the receptacle. The cover plate should be weatherproof FS type if the cord is to be used outdoors. If for indoor use a normal steel cover plate designed for use on a FS box will work fine. If strictly for indoor use, a box called an 1110 utility box, will also work to hold the receptacle.


Why can't you change out a switch for a receptacle?

Electrically there is no reason you couldn't if the neutral exists in the switch box. But in a home, a switch is required just inside every door. So other arrangements would have to be made for that. Replacing a switch with a receptacle would mean there is no longer a switch, of course, for the lights. They would either be on all the time or off all the time. If you need a receptacle at this location, consider installing a combination unit with a switch and single receptacle on the same yoke.


Can you use 14-2 wire to operate a ceiling fan using two switches one for the fan the other for the lights?

On these types of installations an electrician would use a three wire cable set from the switch box to the fixture's junction box. At the fixture's junction box both the fan neutral and the light neutral would be wire nutted together with the incoming neutral from the switch boxes. From the three wire, the white wire would go to the fan and light's neutral wires. The Black would come from the bottom of one of the switches and go to the fan's motor lead. The red wire would come from the bottom of the other switch and go to the light fixture's lead. It can be done with two runs of two wire to the fixture. You will need a two gang switch box for this project to hold the two separate switches. You could use a single gang light switch box if you can still find where duplex switches being sold. A duplex switch is one that has the configuration of a duplex receptacle with the switches being one on top of the other. The cover plate is the same one used for duplex receptacles. To answer this question fully more information is needed. See discuss in the left margin.


What is a strap or yoke on a duplex grounding receptacle?

The yoke or strap is the metal fram that hold everything together and where the outlet attaches to the box.

Related questions

Where can you purchase a wall plate for a four-light switch in a square since this is not a standard switch plate?

If you are talking about a typical 4"x4" box, you can use a pair of combination dual switches (they have the same shape as a standard receptacle, so you could use a plate made for a double duplex receptacle...see for the type of switch I had in mind) .


Do you go from breaker box to receptacle to receptacle?

Yes, that is one combination you can use.


EXPLAIN WHAT WIRES DO IN A RECEPTACLE?

Wires bring the voltage source to the junction box of the receptacle. At this point they are terminated under the screws of the receptacle. With the receptacle screwed to the junction box and the cover plate installed the outlet is ready to be used. The last thing to do is turn the breaker back on to energize the receptacle.


How do you replace a GFCI outlet?

The GFI outlet was there for a reason, such as a bathroom or other location around water where there is more risk of a shock being harmful or lethal. If it was a GFI, keep it a GFI. Also that outlet may be protecting other standard outlets being fed from the GFI. You can only after the house has passed inspection after the house was finished being built. It's a requirement that all new houses have to have a GFI wherever there's water, but it's perfectly legal once you buy the house to do this modification. However, it's highly not recommended unless there's more than one GFI outlet hooked up to the same circuit. If there's more than one, it's optional to take one off and replace it with a standard outlet because you really only need 1 GFI outlet to protect the rest of the outlets on the same circuit. But if it's already there, just leave it as is. Example: power box>GFI>normal>normal>GFI>normal; end; You can take off the second GFI and and every normal non-GFI outlet will function like GFI. If you take off the left one, only the last normal outlet will be GFI protected, the ons to the left wouldn't.


What is a Balaam box?

A Balaam box is a receptacle in journalism for rejected articles.


Is it safe to glue or tape an electrical socket in place?

No, the receptacle needs the screws in place to complete the bond between the metal component of the receptacle to the metal component in the receptacle's junction box. This bond is entirely separate from the grounding of the receptacle.


How do you install a 12v power receptacle on your motorcycle?

Run a fused power line from the receptacle to either the battery for constant Hot or to the fuse box for an ignition controlled receptacle and ground the receptacle either by mounting on a metal surface or run a ground wire from the body of the receptacle to a good chasis ground


How do you extend the electric outlet at the basement?

Parallel connect the new receptacle to a receptacle in the existing circuit. Black (hot) existing to black (new), white existing to white (new), ground existing to ground (new). Make the ground wire coming into the new receptacle box longer so that it can be looped around the ground screw located in the receptacle box first and then connect to the receptacle without having a break in the wire.


240v box outside for a hot tub you need a 110v receptacle Can you wire it off the 240v box?

Using a box that is hire voltage than what you need can cause a short, and even a fire. So using a 240V box, when all you need is a 110v receptacle, wouldn't be a good idea.


Which fiber optic connector looks like a box and snap into a receptacle?

biconic


Can you install a receptacle that is rated for 240 volts to a 277 volt line?

No, it is not safe to install a receptacle rated for 240 volts on a 277-volt line. The receptacle's rating must match the voltage of the electrical circuit to ensure safe operation; using an incompatible receptacle can lead to overheating, damage to equipment, and fire hazards. It is important to always use the right components for electrical installations to prevent accidents and ensure proper functionality.


How do you put a household receptacle on the end of an extension cord?

Yes, the receptacle will have to be terminated in a receptacle box of some kind. Construction usually use an FS type box with a 1/2" hub. A 1/2" strain relief connector is used to hold the extension cord into the FS box. Wire the white wire of the cord to the silver screw, black coloured wire to the brass screw and the green wire to the green ground screw on the receptacle. The cover plate should be weatherproof FS type if the cord is to be used outdoors. If for indoor use a normal steel cover plate designed for use on a FS box will work fine. If strictly for indoor use, a box called an 1110 utility box, will also work to hold the receptacle.