Chalk line is used to mark out the ''conduit run''
It is not hard. 220VAC is standard and common for house hold and residential applications in India.
You will have to run wires from your electric box in your house, I would suggest barring these wires.
A 600 amp service for a residence is not in the normal range of residential wiring. The service will require special metering and installation procedures along with consultation with utility company and the electrical inspector. Most home wiring electricians are limited as to the amount of current their licence will allow them to install. This is usually 200 amps. Two parallel 350 MCM conductors with an insulation factor of 90 degrees C will give you an ampacity of 650 amps.
To make the project 100% perfect use separate conduits spaced 6 inches apart. The length of the run will induce current into the coax even though it is a shielded cable. Common practice when there is close proximity of the two cables is to cross each other at a 90 degree angle to each other. This practice cuts down on the mutual induction into the other wire.
The pipes are PVC electrical conduits.
Chalk line is used to mark out the ''conduit run''
No, the cat 5 wire should cross conduits at an angle of 90 degrees. If the cat 5 wire is installed in conduit then it can be run parallel with the other conduits. Yes they can be installed above the dropped ceilings but tie them up high near the joists.
A $10 120v or 24v relay tied into the controls of both units will do it, if the electrician is smart enough to know how to wire it in.
Those giant highway noise barriers that run for miles along the edge where highways pass through residential areas.
Water is stored behind a dam and possesses potential energy. When it is released and made to run down conduits down the dam to turn turbines the potential energy is converted to kinetic energy which in turn is converted to electrical energy.
Yes, you can run electrical wires in a load bearing wall.
Electrical- there are a few that run on heat energy from gas or kerosene.
Conduit comes in many styles and is used to run electrical wiring in exposed locations in and around your home. It may be a basement, garage, barn, laundry areas, and also exposed areas.