Q: How many 1250 mcm wires will fit in 4 inch emt?
Write your answer...
Submit
Still have questions?
magnify glass
imp
Related questions

What is the smallest size emt conduit that can be used with nineteen 10 gauge thwn wires?

1 1/2 inch


How many wires needed for 220 volts ac though emt?

Two wires are needed for 220 volts.


A hand-operated conduit bender with a shoe for bending 1-inch EMT can also be used to bend?

1/2 inch emt


How many number 10 wires can fit in a 1 EMT conduit?

16 current carry conductors


How many 12 gauge current carrying conductors are allowed in 1 inch EMT?

29


How many No2 Awg THHN wires will fit in a 1 conduit?

According to appendix C of the NEC, 3 #2 awg are permitted in a 1" EMT.


What is the smallest size emt conduit that can be used with three 14 gauge thwn wires and four 6 gauge thwn wires?

This is per the NEC Handbook, 2005 edition. Your municipality may use different rules. I am not an electrician. Per Table 5, chapter 9: Approximate area of 14 ga. THWN is 0.0097 sq. in. Approximate area of 6 ga. THWN is 0.0507 sq. in. 0.0097 * 3 = 0.0291 0.0507 * 4 = 0.2028 ...total area 0.2319 sq. in. Per table 1 chapter 9, you are allowed 40% fill for more than two wires in EMT. So, 0.2319 / 0.4 = 5.7975 sq. in. minimum conduit area, which means you'd have to use 2-1/2 inch trade size EMT, which is 5.858 sq. in. Hope this helps.


What is the function of Electrician's pliers?

To strip electrical wires and to twist mutliple wires together.


What is the code requirement for attaching two pieces of half inch EMT side by side?

Strap the conduit every five feet.


How much is a emt salary per month and what are the qualification?

EMT can earn anywhere from 42000 and 72000 dollars a year. You will need 2 years of basic emt training which can be earned at many universatries.


How many number 12 THHN conductors are allowed in half inch EMT?

According to the 2005 NEC Annex C, table C.1 you are allowed nine #12 THHN conductors in a 1/2" trade size EMT conduit. If your conduit run is any length at all, you would be wise to increase the conduit size to 3/4". as pulling 9 #12's for any length in 1/2" EMT is very difficult.


Where can I find EMT practice tests?

EMT stand for Intermediate practice exams. These practice tests are only to demonstrate the type and quality of EMT. I questions that can be found within our subscription area. These EMT I exams do not include the grading and rationale functionality as do the exams within the paid members area.