answersLogoWhite

0

One or both of the switches is miswired and the two lamps are in series. When everything else fails. Read the instructions.

User Avatar

Wiki User

17y ago

What else can I help you with?

Related Questions

How can I properly wire switches and receptacles in my home electrical system?

To properly wire switches and receptacles in your home electrical system, follow these steps: Turn off the power to the circuit you are working on at the breaker box. Use a voltage tester to ensure the power is off before starting work. Connect the black (hot) wires to the brass screws on the switches and receptacles. Connect the white (neutral) wires to the silver screws on the switches and receptacles. Connect the bare or green (ground) wires to the green screws or grounding terminals. Secure the wires with wire nuts and wrap the connections with electrical tape. Install the switches and receptacles into the electrical boxes and secure them in place. Turn the power back on and test the switches and receptacles to ensure they are working properly. Remember to always follow local electrical codes and regulations when working on your home electrical system.


What is a switched LAN?

Interconnecting a set of LANs using switches is called Switched LAN


What is the ampere specification of switches and sockets used in house wiring?

In North America the standard receptacles and switches are rated at 15 amps. A dryer receptacle is rated at 30 amps and a range receptacle is rated at 50 amps. New code rules are allowing 20 receptacles in some specific locations.


Is a 2001 s-10 Positive Switched or Ground Side Switched?

Mostly positive side switched but it has a couple ground side switches also such as the courtesy lights.


Can dimmer switches go bad and cause issues with controlling the brightness of the lights?

Yes, dimmer switches can go bad over time and may cause issues with controlling the brightness of the lights.


What are 10 switches that can be found at home?

Ten switches commonly found at home include light switches for overhead lights, dimmer switches for adjustable lighting, outlet switches for controlling power to electrical outlets, and three-way switches for controlling lights from two locations. Additionally, you might find toggle switches for fans or appliances, rocker switches for lamps, motion sensor switches for automatic lighting, smart switches for app-controlled devices, GFCI switches for safety in wet areas, and pull-chain switches for ceiling fans or light fixtures.


What are the different options available for controlling a ceiling fan using wall controls?

The different options available for controlling a ceiling fan using wall controls include basic on/off switches, speed control switches, and switches with remote control capabilities.


There are three switches in a building and the building will catch fire if one among the three switches is switched on. How will you identify that switch?

After the building catches on fire.


You have an outlet with three light switches controlling three different lights what is this called?

A triplex outlet. It is a simple device unless one or more of these switches are "3way" switches.


Which types of switches are used in a PC keyboard?

The switched used are most commonly mechanical.


How can I wire a circuit with three switches controlling one light, using a diagram to illustrate the setup?

To wire a circuit with three switches controlling one light, you can use a three-way switch setup. This involves connecting the switches in a specific way to allow for multiple control points for the light. Here is a diagram illustrating the wiring setup for the circuit with three switches controlling one light: Insert diagram showing the wiring connections between the switches and the light fixture.


Why would receptacles have low voltage and the light switches no voltage on the same circuit?

lighting is usually on 15A breakers receptacles on 20A the probability is high that they are not on the same circuit. if they are the same circuit the probability is high that there hasn't been an electrical inspection