Best Answer

A 60A breaker will protect a very large conductor indeed, much larger than an ordinary household water heater would need. Many houses only have a single 60A main fuse!

It would be pointless and dangerous to use a 60A breaker to protect an electrical cable (and appliance) rated for, say, 30 amps. So, you will need to find out the name-plate rating on the water heater before you burn something down.

User Avatar

Wiki User

16y ago
This answer is:
User Avatar

Add your answer:

Earn +20 pts
Q: What gauge wire is required for a 60 amp breaker feeding a water heater 240 vac?
Write your answer...
Submit
Still have questions?
magnify glass
imp
Related questions

What is the wire size required for 1800 watts for lamps?

14 gauge will handle it with a 15 amp breaker. If you use 12 gauge use a 20 amp breaker.


What size breaker should be used for 1500 watt bathroom exhaust fan heater?

20 amp breaker 12 gauge wire assuming its 120 volt


What is the maximum breaker size for these gaug?

You listed no gauge wire. This is the required breakers.14 gauge - 15 amp12 gauge - 20 amp10 gauge - 30 amp8 gauge - 40 amp


What is the maximum breaker size for these gauges wire?

You listed no gauge wire. This is the required breakers.14 gauge - 15 amp12 gauge - 20 amp10 gauge - 30 amp8 gauge - 40 amp


What gauge wire and amp breaker do you use on a stove dryer and hot water heater?

A stove is a two pole 50, and hot water heater i would recommend the same.


What gauge wire is required for a 90 amp breaker?

3 AWG in copper and 2 AWG in Aluminum.


What Size breaker for 6 gauge wire?

You need a 60 amp breaker.


What size main breaker do you need to run 10 gauge wire?

The size of the main breaker depends on the maximum current rating of the 10 gauge wire and the load it will be powering. Typically, a 10 gauge wire is rated for a maximum current of 30 amps. Therefore, a 30 amp main breaker would be suitable for running 10 gauge wire. However, it is important to consult local electrical codes and consider the specific load requirements before making a final determination.


What ampts on the breaker do you needfor a 4500 watt hot water tank?

Assuming this is standard house voltage of 120 VAC your 4500 Watt heater will draw about 37.5 amps. You would normally install a 50A breaker and would have to run 8 gauge wire.


What size wire for 28 amps?

Minimum size is 10 gauge with a 30 amp breaker. To be safe I would install an 8 gauge with a 40 amp breaker.


Can you use 14-3 wire on a 20amp breaker?

No. A 20 amp breaker needs 12 gauge wire.


What size breaker should be used on a 20 amp motor?

30 amp breaker with #10 gauge copper wire