answersLogoWhite

0

What is meant by mcb and dp?

Updated: 10/24/2022
User Avatar

Wiki User

12y ago

Best Answer

MCB = Miniature Circuit Breaker

DP = Double Pole

User Avatar

Wiki User

12y ago
This answer is:
User Avatar

Add your answer:

Earn +20 pts
Q: What is meant by mcb and dp?
Write your answer...
Submit
Still have questions?
magnify glass
imp
Related questions

What is the definition of SPN MCB?

the (mcb) is miniature circuit breaker SPN is Single Pole w/neutral DP is double pole TPN is tripple pole w/neutral)MCB =Miniature circuit breaker b)SPN=Single pole and neutral ( 1 terminal for live and 1 terminal for Neutral cable for wire connection. Pole refers to a power cable connection on the MCB) c)TPN=Triple Pole & Neutral (ie. altogether 4 cable input and 4 cable out from the MCB) d) DP refers to Double Pole (with no specific neutral terminal.Still one pole may be used for that. The A refers to rated Current in amperes. Also important is ( i) the rated voltages which will govern the given in Amperes.(ii) Duty it is meant for eg. lighting , motor power etc. (Motor duty for eg is A3). Also whether AC or C supply.


Which is better TPN or 4P MCB?

TPN is same as 4P MCB TPN means Three Pole and Neutral - four pole MCB. 4P is four pole MCB


What is difference between spn and tpn mcb db?

TPN MCB means Triple pole Neutral Miniature Circuit Breaker where as SPN MCB means single phase Neutral MCB.


When was MCB Bank Limited created?

MCB Bank Limited was created on July 9, 1947.


What rating mcb used for 1.5 t ac?

32A MCB to be used


What is mcb and cb?

MCB = Miniature Circit Breaker CB = Circuit Breaker


What are the differences between a MCB and a CB.?

mcb but cb has 2 and the other one has 3


What do the initials MCB stand for?

Many names of organization and companies are abbreviated with MCB. The most famous MCB initials are for Mauritius Commercial Bank or Muslim Council of Britain.


What is the c curve and d curve in MCB?

c curve & d curve mcb difference


What is the full form of MCB?

The definition of MCB is a miniature circuit breaker, it trips if there is a line to natural fault. Ill add some extra information about the different types. RCD - residual current device = This is what you could separate you're circuits up with by inserting 1 of these in you're consumer unit (if you have lets say 10 circuits it goes like this... rcd-mcb-mcb-mcb-mcb-mcb-rcd-mcb-mcb-mcb-mcb-mcb-main switch. you see the rcd's control 5 circuits each, if 1 of these circuits had an earth fault on it, the rcd will trip and 5 of them circuits will go off, which means you have to keep tripping in you're rcd with an mcb 1 at a time to see which circuit the fault is on. RCBO - residual current breaker with overload protection- These can be installed in place of mcb's and rcd's, the rcbo is an mcb and rcd in 1 breaker. For example, i have installed a consumer unit full of these, in this case if a circuit forms a fault then its only that circuit that goes off. I hope this extra piece of information helps you along and best of luck. <<>> In electrical terminology MCB stands for Miniature Circuit Breaker.


Where are the headquarters of MCB Bank located?

The headquarters of MCB Bank Limited are located in Islamabad. MCB Bank Limited also maintains a principal office which is currently located in Karachi Pakistan.


What are the causes of fire on MCB?

loose screws or corroded cables or over current above breakers rating (faulty breaker not tripping when meant to) internal fault with breaker.