answersLogoWhite

0


Best Answer

60 Hz in North America, 50 Hz in Europe.

User Avatar

Wiki User

15y ago
This answer is:
User Avatar

Add your answer:

Earn +20 pts
Q: What is the Hz rating on 100 Amp household service?
Write your answer...
Submit
Still have questions?
magnify glass
imp
Related questions

What is the amp rating for 14 gauge wire 100 ft .?

Under normal household conditions it is 15 amps.


What is the size of the copper wire for a 100 amp service?

A #3 copper conductor with an insulation rating of 75 or 90 degrees C is rated at 100 and 105 amps respectively.


What is the largest sub panel you can install off from a 60 amp main panel fed by 100 amp service?

If what you state in this question is accurate this is an illegal installation. A 100 amp service can not have any equipment connected to it less that that of the service size. The 60 amp main panel must be a 100 amp panel to be a legal installation.


Do you need to change the wire size going from 100 amp service to 150 amp service?

Yes, the wire size has to be increased. The existing 100 amp service will now probably have a #3 conductor with an insulation factor of 75 or 90 degrees C which is rated for 100 and 105 amps respectively. Increasing to a 150 amp service will use a #1/0 wire size. If you are thinking of an upgrade, skip the 150 amp service and go to a 200 amp panel. New homes are installing 200 amp 42 circuit panels. The extra cost is only reflected in the materials as the labour costs will be the same regardless whether a 150 amp or a 200 amp panel is installed. The wire size for a 200 amp panel is #3/0. With an insulation factor of 75 or 90 degrees C the rating is 200 or 210 amps respectively.


Can you upgrade a 100A main circuit breaker to a higher amp?

I doubt if the 125 amp breaker will fit into a 100 amp box. This is due to the rating of the box only being rated at 100 amps. If this exchange could be made then the service conductors feeding the box must be upgraded to take the 125 amperage that the breaker will allow on the conductor.


How many amps does a 100 amp service supply?

A 100 amp service will supply your electrical current needs UP TO 100 amps.When doing load calculations on a 100 amp panel it can only be loaded up to 80 amps.


Can you install 100 amp service in 200 amp meter base?

No, each size service needs its own meter base.


What is the amp rating of NM wire?

The ampacity or amp rating of all wire is rated by the size of the wire. NM (non-metallic sheathing) wire is no different. In household wiring 14 gauge wire must go on a 15 amp breaker/ 12 gauge goes on a 20 A and 10 gauge goes on a 30 Amp.


Can you tap off of a 200 amp service for 2 100 amp panels?

Yes, but at every reduction in wire size there has to be a breaker sized to the smaller wire size. The wire size for 100 amp panels is recommended at #3 copper conductor. From the 200 amp feeder panel you will require a 100 amp two pole breaker for each of the two 100 amp services. Keep in mind that if you run the 100 amp services close to maximum this will take away the capacity of the 200 amp service for other branch circuits coming off of it. Also keep in mind that if the panels are located, not in the same building as the 200 amp service that the 100 amp panels will be treated as separate services and will have to be constructed like a 100 amp service. This includes ground rods. Also the bonding screw will have to be removed that connects the neutral buss to the panel enclosure.


What gauge wire for service entrance in Wisconsin?

Depends on the size of the service. 100 amp service will require 3 gauge, 150 amp service will require 1/0 gauge, and 200 amp service will require 3/0 gauge.


How many breaker amps will a 200 amp service with no main breaker support?

Check the nameplate on the service panel. There it will tell you what the buss capacity is. On a 200 amp service nothing in the wiring configuration is allowed to be less than that the service rating. In the market there are 200 amp 42 circuit distribution panels.


What size ground wire for 100a service?

A 100 amp residential service requires a size #8 copper wire, it should be insulated in green.