A ratio of 1:40 (meters) is the preferred minimum ratio
No, there shouldn't be any standing water in a sewer line, this is what creates bad bacteria and disease. All waste needs to go down a sewer line and disappear ito the street sewer line. If this is the case, either you have a slight blockage or the sewer line gradient is incorrect. The correct ratio for the gradint of a sewer line must be 1:40 (meters) simpler measurement for slope is 1/4" per foot(ideal). absolute minimum 1/8" per foot(not recommended except where not avoidable)
There are four sewage disposal systems available to the general public. The septic tank, the sanitary sewer, the storm sewer, and the domestic sewer.
There are four major types of sewage disposal systems. The septic tank, the domestic sewer, the storm sewer, and the sanitary sewer are the major types.
1%
1% pitch is min
It should be 3" minimum, preferably 4.
1/8" per foot.
One drain outlet is sufficent provided the drain outlet to the sewer line or to the gully outside has the correct gradient fall.
the minimum velocity at which no solid get deposited in the invert of the sewer. while designing the sewer the velocity should maintained such that no solid get diposited in the sewer. in case of separate sewer a min. velocity of .6m/s should be maintained. it should less than .75m/s in case of combined sewer, .9m/s would be acceptable.
1/8" per foot
Outside diameter (OD) of adjacent manholes (including the bottom slabs) should have minimum of five (5) feet horizontal clearance.