Correction - 2 hot (2 * 120) = 240 volts
common - neutral
U R 100% correct
PS: 240 motor for pool ? hmmm, learn something everyday The cable from the breaker box to the pool should be a 3 conductor. In that 3 conductor cable there should be a bare ground wire (the ground wire is not included in a cable wire count). The pool ground should be connected to that bare wire, not the white neutral. This bare ground wire is then grounded back at the breaker panel to provide a direct path to trip the breaker in case of a short circuit. Code requires a GFCI ahead of the pool load to detect ground faults. See related links below on GFCI's
200 amp is the most common size used in most homes.
Correct - this is common knowledge and you would not need to cite it.
Most common people say a thermometer
The most common types are the regular type, where the only over current protection is provided by the breaker panel. the other most common type is the GFCI (Ground Fault Circuit Interrupter) This type has a built in "circuit breaker" so when it senses a fault in the circuit it trips-this type is the safest as they are more sensitive than circuit breakers in the breaker panel.See related links below.
Organization
silicon type
What common applications of electronic monitoring or surveillance equipment are there?
name four common types of tableside serving equipment?
Common applications of eletronic monitoirng or surveilance equipment
Equipment is not actually bought using common stock rather it is purchased from cash by issuing common stock so journal entry is : [Debit] Equipment [Credit] Cash / bank
The most common types of circuit breaker used are MCBs. (Miniature Circuit Breakers.)The most common type of breaker used in most every residence in the U.S.A. is the non-adjustable trip breaker.
200 amp is the most common size used in most homes.
Various pencilsrulerscaliperscompass
'Symbolizes' is the correct spelling. 'Symbolises' is common in Great Britain.
It sounds like the breaker is unserviceable. Seeing as it supplies 240 volt outlet it must be a two pole breaker. If it is a single handle two pole breaker then one pole set inside the breaker is not disconnecting one of the lines. If it is supplied from two single pole breakers that has a common tie, the common tie might be loose and does not shut off both poles when thrown to the off position. If there is no common tie then both breakers must be turned off to interrupt the 240 volt supply.
pooling resources to buy equipment pooling resources to buy equipment
Equip. or Eq. are the two most common abbreviations for the word equipment.