Wiki User
∙ 14y agoThat is a description of an ordinary "coaxial cable". There are designators for various specific coaxial cables such as RG-58 and RG-59. See the link for more. Sounds like shielded RG-58 or RG-59 used respectively as listed above for cable TV or RG-59 for satellite TV. If the cable is as large as a human average finger it could be shielded 2-way radio cable which usually is run from the base station to the outside antenna.
Wiki User
∙ 15y agoWiki User
∙ 15y agoIn general this would be called a coaxial (co-ax) cable.
These are mostly used for Cablevision and TV antenna signals, 75 ohm coax
A similar type of cable with BNC connectors was used for older Ethernet "ThinNet" networking - (coax Ethernet cabling has been almost totally replaced by twisted pair Ethernet 10BaseT)
http://www.epanorama.net/documents/wiring/coaxcable.html
Wiki User
∙ 14y agocoaxial cable most commonly used for tv signal but can also host internet, phone, and more
Wiki User
∙ 14y agoCo-Axiel Cable - Used in Audio Visual applications
ECC stands for Earth Continuity Conductor. It is a grounding component of the electrical system. An ECC can be a bare conductor, a single conductor or a part of a multi-conductor cable.
The correct answer is....80-conductor IDE ribbon cable.
2 conductor round cable 2 conductor twisted cable
A single-phase cable will have a line and a neutral conductor and, possibly, but not necessarily, an earth (ground) conductor. A high-voltage three-phase cable will have three line conductors. A low-voltage three-phase cable is likely to have three line conductors and a neutral conductor.
The 80-conductor cable and the 40-conductor cable.
yes
THHN is a single-conductor wire typically used in conduit for indoor wiring, while Romex is a brand of non-metallic sheathed cable that contains multiple insulated conductors in a flexible plastic jacket. THHN must be used inside conduit, while Romex can be run along surfaces or in walls without conduit.
Cable faults are normally categorised as (a) conductor-to-earth (ground) faults, (b) conductor-to-conductor faults, and (c) conductor-to-conductor-to earth (ground) faults. In addition to that, we can categorise them by whether they are 'high-resistance' or 'low-resistance' faults.
Coaxial cable, STP cable, UTP cable
The cross-sectional area is one of the factors that determines how much current a conductor can carry -this is regardless of the shape of that conductor's cross section (many conductors are not circular). So the diameter is of not much interest.
In a HT cable there are 2 layers of semiconductor one on the conductor and second on the XLPE insulation. As we know semiconductor behaves as conductor when temperature rises. So when the HT cable is on load its conductor temperature rises due to this the semicon layer which is on conductor behaves like conductor and as a result overall cross section area is increased. now the second semicon layer which is over XLPE on temp rise behaves as conductor and used for dessipating heat out of conductor as the cable heat due to load.
80 conductor IDE cable; 40 conductor IDE cable