Best Answer

Yes, there is no reason why this can not be done. In fact a benefit of this is that every receptacle downstream from this new receptacle will also be protected by the GFCI receptacle.

User Avatar

Wiki User

10y ago
This answer is:
User Avatar

Add your answer:

Earn +20 pts
Q: Can I install a GFCI receptacle from an existing receptacle in the basement?
Write your answer...
Submit
Still have questions?
magnify glass
imp
Related questions

What might happen if the line and load connetions of a feedthrough gfci receptacle were reversed?

Most probably the receptacles downstream from the GFCI would not be protected by the GFCI receptacle.


How do you install multiple GFCI receptacles?

A GFCI receptacle can extend its protection to regular receptacles connected to the output side of the GFCI. Each actual GFCI receptacle should be directly connected to a breaker in electric panel.


Do you need a gfci outlet if you have a gfci breaker?

Not if the GFCI breaker is supplying the circuit you are wanting to put the GFCI receptacle into.


What is the weight of a GFCI receptacle?

8 ozs. and will vary by mfr. for an in-wall receptacle.


If I have 20 amp GFCI receptacle and would like to add another receptacle to the GFCI Does the new plug also need to be 20 amps?

Yes.


How far do you put a GFCI from water?

How far do u put a GFCI receptacle from water


Can you install an electrical switch before a gfci?

Yes, an electrical switch can be installed before a GFCI outlet in a circuit. Just ensure that the wiring is done correctly, following all safety guidelines and local electrical codes. The GFCI outlet should be properly connected to the power source and the switch should be wired to control the flow of electricity to the outlet.


Will another electrical outlet that is in line with a GFCI outlet cause it to kick off?

A down stream receptacle that is connected to the upstream GFCI will be protected. If the downstream receptacle senses a fault the upstream GFCI will trip.


What does the term GFCI receptacle stands for?

The term GFCI stands for Ground Fault Circuit Interrupter.


How many amps does gfci trip at?

GFCI receptacles are designed to trip at around 5 milliamps (0.005 amps) of current leakage to ground. When the GFCI detects this level of imbalance, it quickly shuts off the power to prevent electric shock.


Do you need a gfi plug for a spa if it is being plugged into a gfi circuit?

Yes, it is recommended to have a GFCI (ground fault circuit interrupter) protection for a spa even if it is being plugged into a GFCI circuit. This redundancy provides an extra layer of safety in case of any issues with the existing circuit.


If your wall receptacle has tripped but not at the circuit breaker how can this problem be repaired?

If the wall receptacle has tripped but not at the circuit breaker, it could be a faulty GFCI outlet. Try pushing the reset button on the GFCI outlet itself to restore power. If that doesn't work, you may need to replace the GFCI outlet. Make sure to turn off the power at the breaker before attempting any repairs.