Q: Can you use a 12-3 romax for a double pole 40 amp breaker It is for a mig welder?
Write your answer...
Submit
Still have questions?
magnify glass
imp
Related questions

Should you buy double pole breaker or single pole?

It depends on the specific requirements of your electrical system. Single pole breakers are typically used for 120-volt circuits, while double pole breakers are used for 240-volt circuits. If you are unsure, it is recommended to consult with a qualified electrician to determine the appropriate type of breaker for your needs.


Can a 220 VAC breaker be single pole or does it have to always be a double pole breaker?

A 220 VAC breaker can be single pole or double pole depending on the application. For standard 220 VAC circuits like most household appliances, a double pole breaker is typically used. However, in certain situations where only one hot wire is needed, a single pole breaker can be used for 220 VAC circuits.


Can a double pole 20 amp breaker be used with 12-2 wire for a single 220 circuit?

Yes, a double pole 20 amp breaker can be used with 12-2 wire for a 240V circuit. However, make sure the device you are connecting requires 240V and not 120V. Also, consult local electrical codes and regulations to ensure compliance with safety standards.


Is a double throw 15amp breaker the same as a 30 amp breaker amp?

You have a double pole breaker for 240Volt supply. The maximum current is 15 amp.


Where is the double-pole circuit breaker located?

before the load


Can a double pole circuit breaker be used for 2 different circuits I have a 20 amp double pole breaker want 2 circuits running 14 gauge wire?

can a 20 amp double pole circuit breaker be used for 2 different 120 v circuits using 14 - 2 wire


How do you define a pole in circuit breaker?

A pole In a circut breaker refers to the number of circuts it controls, single pole only controls one, double controls 2 at same time


What three loads in your house would you need a double pole breaker?

Electric dryer, electric range and central air conditioner. Some people also have a 220v outlet in their garage or workshop to run equipment like a welder or air compressor.


What is a 15 amp double pole breaker?

A double pole breaker has one pole attached to one side of your breaker panel's bus or hot leg, and another pole attached to another hot leg or bus, if it is in a residential panel (in the US) each leg of the breaker is 120 volts to ground or neutral and 240 hot leg to hot leg. The 15 amp indicates that the breaker will trip if the circuit exceeds 15 amps across the two outputs of the breaker.


Does a double 50 amp breaker make a 100 amp?

No, a double pole 50 amp breaker protects a 240 volt supply at 50 amps. The number that is on the handle of the breaker is the amperage that the breaker will trip at if an overload occurs on the circuit.


Why do you need a double 30A pole for an electric dryer if you only have one pole left in your box?

The dryer is 220VAC. You need a double pole breaker to get 220 out of a home breaker panel. Perhaps you should contact an electrician who understands wiring so that you don't burn your house down.


Does a double-pole 30A breaker pull 15A per leg and if so why can't 14 gauge be used since 14 is rated for 15A?

A double pole 30 amp breaker can pass 30 amps per pole, therefore #10 wire should be used.