Your L14-30 receptacle has four positions on it. It is rated as a 125/250 volt device. It is classed as three pole four wire grounding. Connect the ground wire to the "G" screw, white wire to the "W" screw. One of your hot wires (might be red) to the "X" screw and the other hot wire (might be black) to the "Y" screw. This connection gives you the potential of 240 volts between "X" and "Y" and 120 volt potential between "W" and "X" and 120 volt potential between "W" and "Y".

User Avatar

Wiki User

15y ago

What else can I help you with?

Continue Learning about Electrical Engineering

Why use 3 wire 240 volt receptacle instead of a 4 wire 240 volt receptacle?

Use the 4 wire if possible. You would only use a 3 wire for an old appliance.You shouldn't if possible. The 3 wire has no neutral wire as the 4 wire does. Som applications require the use of a 3 wire and some don't.


Can you connect a 220 volt stove to a 120 volt circuit?

Yes, this is a safe connection. A range is usually wire rated at 40 amps and the manufactures do not make a 40 amp rated receptacle. The code requires the next highest rated receptacle be used which is a 50 amp rating. This is why the range receptacle is rated at 50 amps. This receptacle is known as a 3 pole 4 wire grounding receptacle, 14-50R 125/250 volt. Black wire to terminal X, red wire to terminal Y, white wire to terminal W and ground wire to terminal G.


How do you add a 240 volt receptacle to 100 amp supply?

The 240 volt receptacle has to have an amperage rating. It is this rating that governs the wire size and breaker size to feed the circuit. The new two pole breaker will be inserted in the 100 amp distribution if space is available and connected to the new wiring that terminates at the new receptacle.


Which one of the folling types of wire can be used with the pressure terminals of a duplex receptacle?

The types of wire you can use on duplex receptacle with pressure terminal are labeled on the receptacle, next to the holes. AWG 14 and AWG 12 are the typical wire gauges used in this application.


Which prong is the hot prong in a plug?

If you are refering to a wall receptacle, the one on the right is the hot side. The left side is the neutral and it's slot is larger that the hot one. The U shaped on the bottom is for the ground pin of the plug.

Related Questions

Where do I put the red black white and copper wires on a 50 amp three prong recepticle?

The red and black wires are your hot wires, which connect to the two brass screws on the receptacle. The white wire is your neutral wire, which connects to the silver screw. The copper wire is your ground wire, which connects to the green screw. Make sure to turn off the power before making any connections.


Can you change outlet to fit old 3 prong outlet?

An old 2 hole receptacle can be changed to a 3 hole receptacle that will accept a 3 prong plug, provided a ground wire is available at the box and connected to the ground (green) lug on the new receptacle. A 2 hole receptacle has a hot and neutral wire, while a 3 hole receptacle will require a ground wire connection -- in addition to the hot and neutral wires.


Why use 3 wire 240 volt receptacle instead of a 4 wire 240 volt receptacle?

Use the 4 wire if possible. You would only use a 3 wire for an old appliance.You shouldn't if possible. The 3 wire has no neutral wire as the 4 wire does. Som applications require the use of a 3 wire and some don't.


How do you wire a three prong twist lock receptacle to a 4 prong male connector in 220V?

To wire a three-prong twist lock receptacle to a four-prong male connector for 220V, you will need to connect the two hots, neutral, and ground wires from the male connector to the appropriate terminals on the receptacle. Make sure to follow the specific wiring diagram for your receptacle and connector to ensure proper installation and safety. If you are unsure or unfamiliar with electrical wiring, it is recommended to seek the assistance of a licensed electrician.


Can you connect a 220 volt stove to a 120 volt circuit?

Yes, this is a safe connection. A range is usually wire rated at 40 amps and the manufactures do not make a 40 amp rated receptacle. The code requires the next highest rated receptacle be used which is a 50 amp rating. This is why the range receptacle is rated at 50 amps. This receptacle is known as a 3 pole 4 wire grounding receptacle, 14-50R 125/250 volt. Black wire to terminal X, red wire to terminal Y, white wire to terminal W and ground wire to terminal G.


Your electric stove has a 3 prong plug your new stove has a 4 prong stove you bought a new 4 prong outlet but on your old outlet it oly has 3 wires no ground wire how do you ground it?

Look in the back of the range receptacle box that is in the wall. The three wires coming in should have a bare ground wire in the cable set. It wasn't brought to the receptacle because there was no place for it on the three wire receptacle If you find it back there under a screw terminal just add another short piece of wire under the screw and then connect the other end of the short wire to the new ground terminal on the new four position receptacle The wire should be equal in size to the size of the wire that exists around the ground terminal now. If the house is so old that the range cable did not have a ground wire in it the code allows a separate green ground #10 wire to be taken from the breaker panel box to the existing range receptacle This wire is to be bonded on each end. At the panel end to the ground buss and at the receptacle end around the ground screw at the back of the box unbroken and then to the new four position receptacle ground lug.


What is the proper installation procedure for a 50 amp 240 volt receptacle?

To install a 50 amp 240 volt receptacle, first turn off the power at the breaker box. Then, connect the red and black wires to the hot terminals, the white wire to the neutral terminal, and the green or bare wire to the ground terminal. Secure the wires with the appropriate screws and cover the receptacle with a faceplate. Finally, turn the power back on and test the receptacle to ensure it is working properly.


Is the wide prong on an electrical plug connected to the black wire?

No, the wide prong is neutral it is the white wire. The narrow prong is hot it is the black wire. The round prong (in a 3 wire plug) is safety ground it is the green wire.


How do you add a 240 volt receptacle to 100 amp supply?

The 240 volt receptacle has to have an amperage rating. It is this rating that governs the wire size and breaker size to feed the circuit. The new two pole breaker will be inserted in the 100 amp distribution if space is available and connected to the new wiring that terminates at the new receptacle.


What is wrong if you changed a four prong to a three prong and the dryer is not heating?

My question is WHY did you replace a four prong dryer plug with a three prong! 220 volt Electric dryers require two hot legs, a neutral and a system ground wire. Sounds as though you shunted one of the hots or the neutral. You need to install a four prong plug of the same configuration and wire it exactly as the original.


How do you wire up 2 120V strands into a 240V if the 3 prong receptacle has 2 hots and a neutral but no place for the grounds and should you just wirenut the grounds and tuck them in the box?

On the three prong 240 v receptacle there shouldn't be a neutral because it's not needed. Should be two hots and the ground and tuck neutrals in box.


How do you run 4 prong 240 volt outlet?

you must run the proper size wire based on the ampacity needed, wire must have four conductors including the gound