365
It would be at least 250 amps, maybe 300 amps.
4/0 (4 ought) in copper will handle 250 amps. The voltage drop at 175 ft. is about 2.14 volts which should be okay.
There are two distinct questions here. To determine the wire size to carry 15000 volts the circuits load amperage must be stated. The wire size for a 550 amp service is, an 800 MCM copper conductor with an insulation factor of 90 degrees C. This conductor is rated at 555 amps. Parallel 250 MCM will give you a total capacity of 580 amps. A triple run of 2/0 will give you a total capacity of 585 amps.
A transformer is a power source. It will provide voltage to a device. Find the voltage rating on the device, say 24V. 250/24 = ~10A.
Yes, this is a safe connection. A range is usually wire rated at 40 amps and the manufactures do not make a 40 amp rated receptacle. The code requires the next highest rated receptacle be used which is a 50 amp rating. This is why the range receptacle is rated at 50 amps. This receptacle is known as a 3 pole 4 wire grounding receptacle, 14-50R 125/250 volt. Black wire to terminal X, red wire to terminal Y, white wire to terminal W and ground wire to terminal G.
15mm approx.
250 watts divided by 12 volts = amps or around 20 amps
There are 1000mA in one amp. So there is 0.25 amp in 250 mA.
The wire rating for a # 12 wire is 20 amps. If you are going to continuously load the circuit you need to de-rate the wire by 80%. This brings the current down to 20 x .8 = 16 amps. The wire rating of a # 10 wire is 30 amps. 30 x .8 = 24 amps.
Depends on the voltage. AMPS X VOLTS = WATTS 250 Watts at 12 V would be about 21 Amps, while 250 watts at 120 volts would be 2.1 amps.
#10 cable is no good for 120 amps, you need #2 cable, and it can be used at a distance of 250 ft.
About 2.25 Amps.
If This Is For Say A House Or A Distrubition Center, I Would Use 000 Which Will Handle Around 240 Amps With No Problem. I`m Sure This Will Handle It. At Anyone Time You Would Or Should Never Have The Loadcenter Maxed Out ( If This Is For A Home ) And If You Fill You Might Or Are Only Running One Item On This Wiring At 250Amp, You Will Have To Install 0000 Cable. Hope This Helps
It would be at least 250 amps, maybe 300 amps.
A wire size of at least 250 MCM (thousands of circular mils) is typically recommended for a current of 312 amps. Using wire size calculators or consulting with an electrician is advisable for specific installations to ensure the correct wire gauge is used for safety and efficiency.
This plug is a pin and sleeve 250 volt three phase four wire device. It is rated at 100 amps. A #3 copper conductor with an insulation factor of 90 degrees C is rated at 130 amps.
A 250 MCM copper conductor with an insulation factor of 75 or 90 degrees C is rated at 255 and 290 amps respectively