You have to purchase a new cord assembly that is designed specifically for ranges. Hardware stores usually carry these cords. Tell the salesperson what you want to do with it and they should give you the right one. On the back of the stove you will find a terminal block with three screws in it. Your newly purchased cord will have 4 wires in it. Red, Black, White, Green. Connect the red wire to the first terminal screw (left). Next the white to the center screw and finally the black to the last terminal screw (right). You are now left with one green wire to connect. There might be a jumper strap from the white wire "neutral" terminal position to the chassis frame of the stove. This must be removed. There should be a ground lug that is bolted to the chassis of the stove. If there isn't a ground lug install one in the place where the jumper strap connected to the chassis frame. There might be a ground lug in the four wire stove kit that you bought, if not buy a #6 ground lug. Put the green wire into the lug and tighten. Make sure the stove receptacle that you are plugging into is turned OFF. Plug the stove into the receptacle. Turn the breaker back on. Stove should be up and running.

User Avatar

Wiki User

15y ago
This answer is:
User Avatar

Add your answer:

Earn +20 pts
Q: Older 3 wire stove to a 4 wire receptacle?
Write your answer...
Submit
Still have questions?
magnify glass
imp
Continue Learning about Electrical Engineering

Can you connect a 220 volt stove to a 120 volt circuit?

Yes, this is a safe connection. A range is usually wire rated at 40 amps and the manufactures do not make a 40 amp rated receptacle. The code requires the next highest rated receptacle be used which is a 50 amp rating. This is why the range receptacle is rated at 50 amps. This receptacle is known as a 3 pole 4 wire grounding receptacle, 14-50R 125/250 volt. Black wire to terminal X, red wire to terminal Y, white wire to terminal W and ground wire to terminal G.


Why use 3 wire 240 volt receptacle instead of a 4 wire 240 volt receptacle?

Use the 4 wire if possible. You would only use a 3 wire for an old appliance.You shouldn't if possible. The 3 wire has no neutral wire as the 4 wire does. Som applications require the use of a 3 wire and some don't.


Can you use one length of 3-wire cable to provide electricity to 2 separate circuits?

In countries that use a single phase split secondary service you can. In modern homes this is the type of circuitry that is used for kitchen split receptacles. On the receptacle the tie bar is removed from the "hot" side of the receptacle. A red wire of the three wire cable is placed on the upper terminal of the receptacle. A black wire of the three wire cable is placed on the lower terminal of the receptacle. The white wire is placed on the opposite side of the receptacle under the silver coloured screw. This will give you a full 15 amps capacity on the top portion of the receptacle and a full 15 amp capacity on the bottom half of the receptacle.


What gauge wire is required to hook up an electric kitchen stove?

Normally a new kitchen stove will require a 50 amp breaker wired with AWG # 6/3 with ground wire.


What is the amp rating on 3 wire?

There is insufficient information. If this is question about a dryer or stove, please specify.

Related questions

Can you connect a 220 volt stove to a 120 volt circuit?

Yes, this is a safe connection. A range is usually wire rated at 40 amps and the manufactures do not make a 40 amp rated receptacle. The code requires the next highest rated receptacle be used which is a 50 amp rating. This is why the range receptacle is rated at 50 amps. This receptacle is known as a 3 pole 4 wire grounding receptacle, 14-50R 125/250 volt. Black wire to terminal X, red wire to terminal Y, white wire to terminal W and ground wire to terminal G.


Why use 3 wire 240 volt receptacle instead of a 4 wire 240 volt receptacle?

Use the 4 wire if possible. You would only use a 3 wire for an old appliance.You shouldn't if possible. The 3 wire has no neutral wire as the 4 wire does. Som applications require the use of a 3 wire and some don't.


Your electric stove has a 3 prong plug your new stove has a 4 prong stove you bought a new 4 prong outlet but on your old outlet it oly has 3 wires no ground wire how do you ground it?

If the old outlet doesn't have a ground wire, you can't properly ground the new 4-prong outlet without running a new ground wire from the outlet to the electrical panel. It's important to consult a licensed electrician to ensure proper installation and safety compliance.


How should old 3 wire stove be wired in panel bare wire to neutral or ground or both?

The bare wire from the old 3-wire stove should be connected to the grounding terminal in the panel. The neutral and ground should not be bonded together at the stove. If the stove requires a 4-wire connection, it's best to run a new 4-wire circuit to meet current electrical codes for safety.


How do you change a 4 prong to a 3 prong plug in on stove?

Go to any hardware or appliance store and purchase a 4 prong to 3 prong adapter. There is no adaptor available for this , you must change the cord set on the stove to a three wire cord. Remove the cover over the terminal housing. note the way the terminals are laid out and the way the wires are landed on them. Remove the wires from the terminals and the cord from the connector. Install the three wire cord and land the black and red wires back to the terminals. The white wire goes back to its' respective terminal, but you must also ground the stove chassis to this terminal with a bonding strap. This strap will go from the white wire terminal to where the green wire was landed in the four wire cord. This strap usually will come with a new stove, it is flat, made of copper with a hole in each end, if you do not have one, make it out of # 10 bare copper wire. Your stove manual may also explain how to do this.


How do you wire a 3 wire 240 volt stove to a 240 volt 4 wire feed?

Change the cord/plug on the stove to a four wire cord/plug. When installing the new plug remove the grounding strip that connects the center lug in the stove wiring block to the frame of the stove. Connect the white wire from the new plug to the center lug. Connect the green wire from the plug to the stove frame.


Can you use one length of 3-wire cable to provide electricity to 2 separate circuits?

In countries that use a single phase split secondary service you can. In modern homes this is the type of circuitry that is used for kitchen split receptacles. On the receptacle the tie bar is removed from the "hot" side of the receptacle. A red wire of the three wire cable is placed on the upper terminal of the receptacle. A black wire of the three wire cable is placed on the lower terminal of the receptacle. The white wire is placed on the opposite side of the receptacle under the silver coloured screw. This will give you a full 15 amps capacity on the top portion of the receptacle and a full 15 amp capacity on the bottom half of the receptacle.


Can you change outlet to fit old 3 prong outlet?

You can use a grounding adapter to convert a 3-prong outlet to fit a 2-prong outlet, but this may not provide grounding protection. It is recommended to hire a professional electrician to upgrade the outlet to a proper 3-prong outlet for safety.


How do you wire a receptacle from two switches one is 3 way one is single pole?

You cannot wire a single pole switch and 3 way switch together.


You are replacing a 3 wire plug to a 4 wire outlet but the stove is set up for a 3 wire and you have a 4 wire plug to switch over but there is no place for the ground wire to go?

The range 4 wire plug kit should have with it a grounding lug that connects to the frame of the stove. If not buy a small #2 lug and bolt it to the frame of the stove. This is the attachment point for the fourth green ground wire from the new range cord assembly.


Is there an adapter for a NEMA 14-30 plug and a NEMA 10-30 receptacle?

A NEMA 14-30 is a 3 pole 4 wire grounding receptacle rated at 30 amps 125/250 volts. A NEMA 10-30 is a 3 pole, 3 wire non grounding receptacle rated at 30 amps 125/250 volt.As the NEMA 10 device has no ground terminal on it, it is not a standard receptacle device so no adapter is made for it.


How do you wire a 4 prong dryer cord to a 3 wire receptacle?

Using a red wire nut hook the 3 wires (of the same color) together with a short piece of wire of the same color. You now have 4 wires tied together. Now take the other end of the short wire and attach it to the outlet on the correct screw Do the same with the other 2 wires Please keep in mind to make sure the wire nut has securely fastened the wires. Loose connections cause heat which cause fire If you do not completely understand this answer please contact a qualified electrician