In conduit? direct burial? distance?
Poly Vinyl Chloride is made from two main ingredients. These ingredients are chlorine and ethylene both of which are needed to make PVC conduit . UV inhibitors are also added to the ingredients to prevent degradation from exposure to the sun's rays.
If the service stack is supported by a support structure and the utility feed drop is not supported from the conduit, the size of the conduit can be 1 1/4". If the service stack is used to support the utility feed drop then the conduit has to be 2" schedule 40 conduit. The reasoning behind this is that if in a storm a tree limb falls across the service drop, the lighter weight conduit could bend and pinch the wires in the stack and short out. This would be ahead of the main service breaker and the only protection for the wire would be the primary fuse at the transformer. Theoretically this amperage could rise to 50000 amps before the primary fuse blows. A schedule 40 service stack if supported, as the code requires, will withstand most tree falls. What is most likely to happen is that the utility connectors will pull apart leaving the service stack intact.
If the sub panel is in the same building remove the bonding screw that bonds the neutral bar to the panels enclosure. Remove the ground from the second ground rod. The sub panel is grounded by the ground wire from the sub panel's feeder. If the panel is separate from the main building treat the sub panel as a separate service. It will need its own ground rods and ground wire from the rods to the neutral bar of the sub panel. Leave the bonding screw in. There will be no ground wire in the conduit between the two services.
Normally the main is on the top but you can install a service panel with the main on the bottom unless local codes prohibit it.
A tee joint in the electrical trade is a conduit fitting. It is used in conduit work where there needs to be a device connected into the main conduit run. An example of this is where a light switch needs to be installed into the conduit run. The main conduit run starts at the distribution panel and proceeds to a lighting fixture. On the way a switch is needed to operate the light fixture. In the main conduit run a tee fitting is installed so as to pick up the switch for the fixture. When the conduit system is complete the wire is then drawn in. The "hot" conductor is pulled to the tee fitting and then diverts to the switch box to pick up the switch and then back up the same conduit to the tee fitting and then on to the lighting fixture. Splices are not usually made in tee fittings.
There are a few fundamental principles of mechanics. The main fundamental principles are space, time, mass and force.
The three main principles of Greek aesthetics are harmony, proportion, and unity. These principles guided Greek art and architecture, emphasizing balance and beauty in their creations.
i need an answere
bob
Connection cords run through a conduit box so a to prevent accidental electrocution. Running the cords through the box ensures that the connections function properly and are protected as well.
list the main types of representative bodies relevant to the edducation sector
The General Assembly and the Security Council are the two main bodies of the UN.
The main reason for connecting a ground wire to the end of a conduit is to ensure that the conduit itself is properly grounded. This helps dissipate any stray currents or faults, reducing the risk of electrical hazards and providing a path for fault currents to travel safely to ground.
Accountancy is the means by which financial information is communicated. Basic principles include the cost, matching, revenue and expense principles.
The main principles of building are safety, durability, functionality, and aesthetics. These principles ensure that the structure is structurally sound, long-lasting, serves its intended purpose effectively, and looks visually appealing.
Patience, Concentration, Clear Thinking, Balance In Art Sketch Are The Main " ART PRINCIPLES".