The breaker you use is determined by the size of the wire in the wall not by what is being connected to that circuit. If you have 14/2 wire then use a 15 amp breaker. If you have 12/2 wire then use a 20 amp breaker. The breaker protects the wiring not the item connected.

User Avatar

Wiki User

βˆ™ 11y ago
This answer is:
User Avatar
User Avatar

Eneji Ezekiel

Lvl 1
βˆ™ 3y ago
What is the meaning of 12/2 wire?
More answers
User Avatar

ProfBot

βˆ™ 1mo ago

For a 1.5 hp air conditioning unit, it is recommended to use a circuit breaker with a rating of at least 15 amps. This will ensure that the breaker can handle the starting current surge of the compressor without tripping. It is important to consult the manufacturer's specifications for the exact breaker rating required for your specific air conditioning unit to ensure safe and proper operation.

This answer is:
User Avatar

Add your answer:

Earn +20 pts
Q: What best breaker rating for 1.5 hp air con unit?
Write your answer...
Submit
Still have questions?
magnify glass
imp
Continue Learning about Electrical Engineering

What size breaker you would use for a 110 volt window air conditioning unit?

Breaker sizing is dependant on what the load amperage is that the breaker is connected to. If the amperage is not given but just the wattage, use this equation I = W/E. Amps = Watts/Volts. This air conditioner unit should be on a dedicated circuit receptacle. On these types of loads the conductor can only be loaded to 80% of the conductors rating. So a 15 amp breaker times 80% = 12 amps or Watts = Amps x Volts, 12 x 120 = 1440 watts. A 20 amp breaker times 80% = 16 amps or Watts = Amps x Volts, 16 x 120 = 1920. Once the breaker is sized remember to use the correct wire size to correspond with the amperage of the breaker.


How do you calculate the watts of a central air and heat unit?

You should not have to calculate the watts of the unit. All the information that you need will be on the nameplate of the unit. It is this information that electricians use to calculate the conductor size and breaker to supply the power to the unit.


What is the difference between Air circuit breaker and Vacuum circuiut breaker?

"Air" and "Vacuum" describe how the breaker extinguishes the arcing current. An Air breaker opens far enough that the dielectric strenght of air is enough to extinguish the arc. A vacuum breaker's contacts are in a vacuum. Oil breakers use oil. SF6 breakers use SF6 gas to extinguish the arc.


Why would plugging in an Air Conditioning unit in a wall receptacle blow a fuse?

The fuse (or circuit breaker) rating has been exceeded. I'm assuming you do NOT have the AC unit connected to a dedicated circuit. Lets say you have a 15 amp circuit breaker and the AC unit draws 12 amps and other items on the same circuit draw an additional 5 amps. The total amp draw of 17 amps exceeds the circuit design capacity; so the breaker trips to prevent an electrical fire. If you have old style fuses, NEVER EVER replace a fuse with a higher rated one! I'm sure you'd have problems with your homeowners insurance paying out when your house burns down. Have an electrician run a new dedicated circuit for the AC unit and you should be good to go.


What is the acceptable value of contact resistance in 415V air circuit breaker?

415v air circuit breaker acceptable value of 0.01 ohms and lessthan

Related questions

What best breaker rating for 1.5 hp air-con unit?

The breaker you use is determined by the size of the wire in the wall not by what is being connected to that circuit. If you have 14/2 wire then use a 15 amp breaker. If you have 12/2 wire then use a 20 amp breaker. The breaker protects the wiring not the item connected.


What amp breaker for 220volt air conditioner?

For a 220-volt air conditioner, you would typically need a double-pole circuit breaker with a rating between 15-amp to 30-amp, depending on the specific requirements of your air conditioner unit. It's important to consult the manufacturer's specifications or an electrician to determine the correct amperage for your particular setup.


How do you reset your central air unit?

There is no reset button on a central air unit, there is a small breaker or fuse box outside next to the unit, it is possible the fuse is blown or breaker tripped.


What size circuit breaker for a 1 ton air conditioner unit?

For a 1 ton air conditioner unit, the circuit breaker size typically ranges from 15 to 20 amps. The exact size needed will depend on the specific model and requirements of the air conditioner, so it is best to consult the manufacturer's specifications or an electrician to determine the appropriate circuit breaker size for your unit.


What size amp circuit breaker should be used for a Rheem RALB36JAZ?

A Rheem RALB36JAZ air conditioning unit typically requires a 30 amp circuit breaker to operate safely. It is important to match the amp rating of the breaker with the requirements of the unit to prevent electrical issues and ensure safe operation.


What is the energy rating on this Air conditioning Unit?

The Energy efficiency rating for the LG 3850 BTU Air Conditioner/Heater unit is 9.7.


Is a 40 amp circuit breaker ok for a 30 amp air conditioner?

No, it is not recommended to have a circuit breaker with a higher amperage rating than the device it is protecting. In this case, you should use a 30 amp circuit breaker for a 30 amp air conditioner to ensure proper protection from overcurrent.


What is the abbreviation AIR as an electrical unit?

Amp Interrupt Rating


Can a 100 amp breaker handle 5 air conditioners?

No, a 100 amp breaker is not sufficient to handle 5 air conditioners. Each air conditioner typically requires its own dedicated circuit with an appropriately sized breaker based on the unit's electrical requirements. You would need multiple circuits and breakers to safely power 5 air conditioners.


Why would a higher amp breaker trip before a lower amp breaker?

Need more information. It doesn't seem rationale that they are protecting the same circuit unless you are substituting one for the other for a test. A unit like an air conditioner may have multiple breakers and a higher value breaker may trip because the load it is connected to is drawing current in excess of the rating of breaker.


Can you use a 20 amp breaker for window unit air conditioner?

Yes, a 20 amp breaker is suitable for a standard window unit air conditioner. Make sure to check the manufacturer's specifications to ensure compatibility.


What ser rating should you buy in an air conditioning unit?

14.0