40 awg

<<>>

The above answer is incorrect. A #40 wire is smaller that telephone wire which is #22 awg.

A #8 copper conductor with an insulation factor of 60 degrees C is rated at 40 amps. For a built in safety factor, a #8 conductor with an insulation factor of 75 or 90 degrees C has a rating of 45 amps.

User Avatar

Wiki User

13y ago

What else can I help you with?

Continue Learning about Electrical Engineering

How do you solve for the size of wire when the given is kva?

The V stands for volts and A is amps. If for example you have a 12kVA device and are running off a voltage of 120 volts then Amps = 12000/120 = 100. You then use the calculated amps in a wire size table to get the correct size.


What size breaker do you need for two 60W bulbes 110 volts?

It is not the number of bulbs that you worry about. It is the wire size that is your concern. If the circuit is wired with AWG 12/2 wire then use a 20 amp breaker. If it is wired with a AWG 14/2 wire then use a 15 amp breaker. You are protecting the wiring with the correct size breaker.


Can you use 40 amp breaker for your lights and plug ins?

If you are referring to house wiring then the answer is no. A breaker protects the wire size that is connected to the breaker. In home wiring most homes are wired with a #14 wire which is rated at 15 amps. That is why the wire is protected by a 15 amp breaker. The correct wire size to connect to a 40 amp breaker is a #8. This size wire is too large to connect to receptacles an light fixture terminals.


What size conduit is correct for 10-3 gauge wire?

You can pull 10 #3 gauge wires in a 2 1/2" conduit.


What size wire do you need to run for 30 amp service to travel trailer 400 feet single phase 110 volt?

Presuming that you would like the least expensive installation, the following is calculated on overhead aluminum wire. The wire size needed to hold the voltage drop to 3% would be 3/0 MCM. If the installation could be run on 240 volts then the wire size can be reduced to #2.

Related Questions

How to calculate the best wire size to use with a 10-32 UNF-2A thread?

10-32 unf-2a &lt;&lt;&gt;&gt; The wire size does not need to be calculated. Use a wire terminal end that crimps to the wire. These terminal end come in various wire sizes and bolt hole sizes. Pick the correct end for the wire size you are using and then in that wire size range, pick the correct bolt hole size that fits the bolt.


What is the recommended wire size for a range installation?

The recommended wire size for a range installation is typically 8-gauge wire.


What is the recommended wire size for an electric range?

The recommended wire size for an electric range is typically 8-gauge wire.


What is the recommended wire size for a 50 amp range?

The recommended wire size for a 50 amp range is typically 6-gauge wire.


What is the recommended wire size for an electric range installation?

The recommended wire size for an electric range installation is typically 8-gauge wire.


What size wire should be used for a range?

The size of wire needed for a range depends on the electrical requirements of the appliance. It is recommended to consult the manufacturer's specifications or a qualified electrician to determine the appropriate wire size for your specific range.


Wire size for an electric range?

The wire size for an electric range depends on the electrical load required by the range. Generally, a 40-amp double pole breaker with 8-gauge wire is sufficient for most residential electric ranges. However, it is essential to consult with a qualified electrician to determine the correct wire size based on the specific requirements of your electric range and local electrical codes.


Does ordinary wire burn out easily?

Not if it is secured and tightened properly and has the correct size breaker installed for the wire size used.


Why do I keep blowing my 40amp ignition fuse on my 1997 Tahoe?

The control wire to the solenoid may be deteriorated and shorting out. Or, you may have a bad starter.


What is the appropriate wire size for a 40 amp 240 volt circuit?

The appropriate wire size for a 40 amp 240 volt circuit is typically 8 AWG (American Wire Gauge) for copper wire or 6 AWG for aluminum wire. It is important to consult with a licensed electrician to ensure the correct wire size for your specific installation.


What is the recommended wire size for a subpanel installation?

The recommended wire size for a subpanel installation is typically determined by the amperage of the subpanel. It is important to consult the National Electrical Code (NEC) or a qualified electrician to ensure the correct wire size is used for the specific installation.


What is the recommended wire size for a 200 amp sub panel installation?

The recommended wire size for a 200 amp sub panel installation is typically 2/0 or 3/0 copper wire or 4/0 aluminum wire. It is important to consult with a licensed electrician to ensure the correct wire size is used for your specific installation.