This depends on how many wires you need to put through the conduit. Typically you would figure out what size wire you need to handle a given load, and then find the smallest conduit you could possibly put those wires in. I'd actually need to know what type of conduit, also. Size your wire first, then your conduit. If you don't know how to size your wire, call an electrician. If you do it wrong you will start a fire. Once you've got your wire size, NEC Table C1 for EMT or C2 for PVC should head you in the right direction. ----
If you do not understand the work well enough to accomplish it yourself properly and safely, don't try it. Consult a professional electrician, as they are proficient enough to do it properly and safely. When working on electrical circuits and equipment, make sure to de-energize the circuit you will be working on. Then test the circuit with a definitive means to make sure it is off (multimeter with metal tipped leads, voltage tester with metal tipped leads, etc., not a non-contact tester, which is non-definitive.)
53
Conduit Installation: 9 Steps Step 1: Mark Conduit Placement: Using a measuring tape, mark the locations where the conduit will be installed, including entry and exit points, bends, junction boxes, and supports. Step 2: Cut and Prepare Conduit: Measure the required length for each conduit section based on your markings. Use a conduit cutter or hacksaw to make clean, straight cuts on the conduit. Step 3: Install Conduit Fittings: Attach the appropriate conduit fittings, such as elbows, couplings, or connectors, to the conduit sections. Step 4: Mount Conduit Supports: Install conduit straps or clamps at regular intervals along the conduit route. Step 5: Assemble the Conduit System: Connect the conduit sections and fittings together, ensuring a snug fit. Apply PVC conduit cement or glue to the inside of the fittings before joining them to ensure a watertight seal. Step 6: Pull Wires: Attach a fish tape or draw wire to the starting point of the conduit system. Carefully feed the fish tape through the conduit, pulling it along the desired path. Use lubrication, if necessary, to ease the wire pulling process. Step 7: Install Conduit Accessories: Install conduit bodies, junction boxes, or other accessories as needed for wire splices, changes in direction, or access points. Step 8: Verify and Secure Connections: Double-check all connections, ensuring they are properly aligned, secure, and free from any gaps or looseness. Step 9: Conduct Final Inspection: Inspect the entire conduit system to ensure it is properly aligned, securely mounted, and meets safety standards. Check for any visible defects, such as misalignments or damaged conduit. That's it.
Answer for USA, Canada and countries running a 60 Hz supply service.It is not a recommended procedure. Depending on what size service entrance cable it is the wire size will be too large to fit into the breaker and range lugs. Cutting strands off of a larger size wire to fit into the lugs is not acceptable. If this is new construction then the electrical inspector will reject the installation for not using the properly sized cable to feed the range. Use the proper size cable and feel free that there is not going to be any problems further on. The wire should be 3 conductor #8 fed from a two pole 40 amp breaker.
If 16mm is the overall diameter of the cable, yes - If that's the diameter of one core, then no.
The offset is the preset distance that is marked on the shoe of the bender. This preset mark allows for shrink back when bending. It allows you to make a perfect bend if a conduit run comes to a wall and has to go up the wall. It takes into account the outside diameter of the conduit and adds it to the shrink back of the bend to make the conduit fit exactly up against the 90 degree angle of the wall.See Sources and Related links below.
The wire to conduit chart provides information on the maximum number and size of wires that can safely fit inside a conduit based on the conduit size.
The wire conduit chart provides information on the maximum number and size of wires that can safely fit inside different types of conduit. This helps electricians determine the appropriate conduit size for a specific wiring installation.
A wire fill chart provides information on the maximum number and size of wires that can fit within a specific conduit or raceway.
Typically, only one 12/2 wire can fit in a 1/2 inch conduit.
The purpose of the NEC conduit fill table is to provide guidelines on how many wires of a certain size can safely fit into a conduit. By referencing the table and considering the number and size of wires needed for a specific application, one can determine the appropriate size of conduit to ensure proper installation and compliance with electrical codes.
9 - Is this a test answer or do you just want to know for a project you're doing? Take a look at NEC chapter 9 - tables 4 and 5 (in the 2005 edition at least)
The electrical conduit fill chart provides information on the maximum number and size of wires that can safely fit within a conduit based on the conduit size and type of wires being used. This helps determine the appropriate capacity for wiring within a conduit to ensure safety and compliance with electrical codes.
The Cat 6 conduit fill chart is a reference tool that provides guidelines on how many Cat 6 cables can fit into a conduit of a specific size. By using this chart, one can determine the appropriate conduit size needed to accommodate a certain number of Cat 6 cables, ensuring proper installation and preventing overcrowding that can affect performance.
In a 3/4 conduit, you can fit up to three 12/2 wires.