For a 100 Amp breaker panel it would be 2 AWG. For 150 Amps it would require 2/0 (2 ought) aluminum wire.
Wiki User
∙ 12y agoIn North America the standard sizes for breakers are 15, 20, 30, and 40 amps. The 15 amp size breaker is used in general circuit wiring. The 20 amp size breaker is used for dedicated appliance receptacles, hot water tank and baseboard heating. The 30 amp size breaker is used for a clothes dryer. The 40 amp size breaker is used for the electric range.
The size breaker you use is determined by the size wire used in the circuit. If you use AWG #12/2 wire then use a 20 amp breaker. If you use AWG # 14/2 then use a 15 amp breaker.
50 amp breaker wired with AWG # 6 wire.
A 40 amp breaker is used in conjunction with AWG # 8 copper wire. The black and red wires are connected to the breaker. The ground wire is connected to the ground bar and the white wire is connected to the neutral bar.
LRA (locked rotor amps) is not used to calculate the breaker size. Breaker's are used to protect the size of the conductor that is connected to it. Motor calculations are based on the motor's FLA (full load amps).Conductor size is 125% of the motor's FLA.Breaker size is 250% of the motor's FLA.This is the only occasion when the breaker is sized larger that the conductors maximum amperage rating. This is due to the motor drawing up to 300 to 600% of its FLA when starting.If you state the motor's wattage, voltage or amperage this calculation can be calculated here.
Don't use aluminum wire inside the house.
2.5 sq mm or 4.Sq mm coil is used for breaker in industries
In North America the standard sizes for breakers are 15, 20, 30, and 40 amps. The 15 amp size breaker is used in general circuit wiring. The 20 amp size breaker is used for dedicated appliance receptacles, hot water tank and baseboard heating. The 30 amp size breaker is used for a clothes dryer. The 40 amp size breaker is used for the electric range.
The size breaker you use is determined by the size wire used in the circuit. If you use AWG #12/2 wire then use a 20 amp breaker. If you use AWG # 14/2 then use a 15 amp breaker.
The breaker size for a TNIA-10 wire depends on the maximum current carrying capacity of the wire, which is typically indicated on the wire's packaging or in its specifications sheet. You should select a breaker that is rated slightly higher than the wire's maximum current capacity to ensure safety and avoid overloading the wire. It is recommended to consult with a qualified electrician for specific guidance on breaker sizing for your installation.
For a standard size refrigerator, a dedicated 15 amp circuit is used.
50 amp breaker wired with AWG # 6 wire.
Aluminum foil is a thin, flexible sheet of aluminum used for wrapping food or covering surfaces, while aluminum rod is a solid cylindrical piece of aluminum commonly used in construction or manufacturing. Aluminum powder is a finely ground form of aluminum used in various applications like paints, explosives, and fireworks. Each form of aluminum has different properties and uses based on its shape and size.
Depends on the wire size used in the circuit. If you use AWG # 14 wire you must use a 15 amp breaker. If it is wired with AWG # 12 wire then you use a 20 amp breaker. If a AWG # 10 wire is used then a 30 amp breaker is required. The breaker protects the wiring from overheating so you must use the proper size breaker for the wire used.
No, absolutely not. The breaker is there to protect the wiring within that circuit from overheating and catching on fire. If you add a larger breaker and the wire stays the same the wire is no longer protected by the correct amp breaker. You could cause a fire. The breaker must match the size wire being used. Do this and you risk burning your home to the ground and possibly killing your family.
A typical home entertainment system may require a 15-amp circuit breaker. It's important to ensure the total power consumption of all components does not exceed the amp rating to prevent overloading the circuit. It's recommended to consult an electrician for proper sizing and installation.
30 amp breaker with #10 gauge copper wire