Related questions

What size wire would you use on a 30amp breaker?

AWG # 10 wire.


What size conduit for 200 amp service?

50 mm or 2 inch will handle the 3/0 wires for a 200 amp service.


What is the required wire size for 100?

A 100 amp service requires that you use AWG 4 copper wire or AWG 2 aluminum wire.


What size wire for 100 amp panel in detatched garage?

i just left lowes an they told me to run 100 amp to my building i would need wire size 2-2-2-4 alumninum and run it in conduit the lowes around here does not sell copper wire that size


What size of electrical wire need to pass 50A?

Use AWG #6 wire.


What is the minimum wire size for a 30Amp breaker?

The minimum wire size for a 30Amp breaker is typically 10 AWG for copper wire and 8 AWG for aluminum wire, according to the National Electrical Code (NEC). This wire size is necessary to safely carry the amount of current without overheating.


How big of breaker do you use for 115 volt?

Depends on the wire size used in the circuit. If you use AWG # 14 wire you must use a 15 amp breaker. If it is wired with AWG # 12 wire then you use a 20 amp breaker. If a AWG # 10 wire is used then a 30 amp breaker is required. The breaker protects the wiring from overheating so you must use the proper size breaker for the wire used.


What size amp circuit breaker should be used for 110 outlet?

The size breaker you use is determined by the size wire used in the circuit. If you use AWG #12/2 wire then use a 20 amp breaker. If you use AWG # 14/2 then use a 15 amp breaker.


What size wire is required for 120v 5amp 250ft?

Use AWG #10 wire on a 20 amp breaker.


Size fuse for 12 AWG wire?

Use a 20 amp fuse or breaker.


What size pipe and size aluminum wire are required for a 100A sub panel off a 200A main service?

For a 100A subpanel, a minimum of 1.5-inch Schedule 80 PVC conduit or 1.25-inch rigid metal conduit is recommended. As for the aluminum wire, for a 100A feeder, you would typically use 1/0 AWG aluminum wire for a 3-wire setup or 2/0 AWG aluminum wire for a 4-wire setup. Always consult local electrical codes and a licensed electrician for precise specifications for your installation.


What size grounding wire do you use as the 4th wire running in your conduit from your 200 amp meter box to your 200amp service panel this is the ground wire from box to box?

For a 200 amp service, you would typically use a 4/0 AWG copper wire for the grounding wire running between the meter box and the service panel. This size is suitable for carrying the necessary current and providing proper grounding protection for the electrical system.